Title: Caracterização química e metalográfica dos aços inoxidáveis de implantes removidos de pacientes
Author: Silva, Elison da Fonseca e
Oliveira, Luiz Fernando Cappa de
Resumo: OBJETIVO: Este trabalho estudou a composição química e metalográfica (microestrutura, tamanho de grão, teor de inclusões) de aços inoxidáveis austeníticos, desenvolvidos para aplicações como biomateriais, utilizados na fabricação de implantes ortopédicos. MÉTODO: Foram analisados doze implantes removidos de pacientes afetados por quadro inflamatório. As análises químicas foram desenvolvidas pelas técnicas Espectrometria de Emissão Ótica e Microanálise por Dispersão de Energia (EDS) e o tamanho de grão foi determinado por microscopia ótica e Microscopia Eletrônica de Varredura (MEV) conforme norma ASTM E 1382 97. RESULTADOS: Observou-se que, todos os implantes apresentavam tamanho de grão superior ao recomendado pela norma, constatou-se também a presença de ferrita delta em dez dos doze implantes removidos, que de acordo com a norma ASTM F138-92 não deveriam ser percebidas microscopicamente com um aumento de 100 vezes. CONCLUSÕES: Em oito casos existe forte indicação de que as inflamações foram desencadeadas pela corrosão por pite. Nivel de Evidência III, Revisão sistemática de Estudos .
Abstract: Objective: This study examines the chemical and metallogra-phic composition (microstructure, grain size, inclusion content) of austenitic stainless steel developed as biomaterials for used in the manufacture of orthopedic implants. Method: An analysis was carried out of twelve implants removed from patients affected by inflammation. Chemical analyses were carried out using Opti-cal Emission Spectrometry and Energy Dispersive Microanalysis (EDS), and the grain size was determined by optical microscopy and scanning electron microscopy (SEM) according to ASTM Standard E 1382 97. Results: It was observed that all the implants had a larger grain size than is recommended by the Standard. The presence of delta ferrite was also observed in ten of the twelve implants removed, which according to ASTM Standard F138-92, should not be perceived microscopically under magnification of 100x. Conclusions: In eight cases, there is a strong indication that the inflammation was triggered by pitting corrosion. Level of Evidence: Level III, Systematic review of studies.
Keywords: Aços inoxidáveis
Próteses e implantes
Materiais biocompatíveis
Corrosão
Stainless steel
Prostheses and implants
Biocompa- tible materials
Corrosion
CNPq: -
Language: por
Country: Brasil
Publisher: -
Institution Initials: -
Access Type: Acesso Aberto
DOI: http://dx.doi.org/10.1590/S1413-78522011000500003
URI: https://repositorio.ufjf.br/jspui/handle/ufjf/8613
Issue Date: 2011
Appears in Collections:Artigos de Periódicos



Items in DSpace are protected by Creative Commons licenses, with all rights reserved, unless otherwise indicated.