https://repositorio.ufjf.br/jspui/handle/ufjf/5426
File | Description | Size | Format | |
---|---|---|---|---|
andreiafialhorodrigues.pdf | 1.19 MB | Adobe PDF | View/Open |
Type: | Tese |
Title: | Avaliação da influência do volume do campo de visão na determinação da densidade mineral em tomografia computadorizada de feixe cônico e tomografia computadorizada multislice |
Author: | Rodrigues, Andréia Fialho |
First Advisor: | Vitral, Robert Willer Farinazzo |
Co-Advisor: | Campos, Marcio José da Silva |
Referee Member: | Gravina, Marco Abdo |
Referee Member: | Santiago, Rodrigo César |
Referee Member: | Quintão, Cátia Cardoso Abdo |
Resumo: | As imagens de tomografia computadorizada de feixe cônico (TCFC) têm sido utilizadas para a avaliação da qualidade óssea, entretanto algumas variáveis inerentes ao exame parecem influenciar os valores de densidade obtidos, sendo que a influência do volume do campo de visão (FOV) ainda não foi completamente explicada. O objetivo deste estudo foi determinar os efeitos do volume do FOV no valor da densidade em TCFC e tomografia computadorizada multislice (TCMS). Um objeto teste composto por três cilindros de acrílico contendo água destilada, gesso e óleo de motor foi construído e inserido em um cilindro de acrílico completamente preenchido com água destilada. O objeto teste foi escaneado com uma TCFC e com uma TCMS, utilizando três tamanhos de FOV: 8x8cm, 16x8cm e 16x13cm. A densidade de cada material foi avaliada em 40 regiões de interesse posicionadas nos cortes axiais. Nos exames de TCFC, houve diferença significativa entre os valores de densidade dos diferentes FOVs para os três materiais. Já nos exames de TCMS houve diferença significativa somente para o óleo. Os valores de densidade mostraram significante correlação entre os exames de TCFC e TCMS para o gesso em todos os FOVs. A água não apresentou correlação significante entre os exames de TCFC e TCMS com os FOVs utilizados. O óleo não apresentou correlação no FOV 8 x 8mm e apresentou uma baixa correlação nos FOVs 16 x 8mm e 16 x 13mm. Os valores de densidade determinados em imagens de TCFC sofreram interferência significativa pela variação do tamanho do FOV. Os valores de densidade obtidos em exames de TCMS apresentaram diferença estatisticamente significante somente para o óleo. |
Abstract: | Computed tomography cone beam (CBCT) scans have been used to evaluate the quality of bone. The values of density seem to be influenced by some CBCT inherent variables. However, some variables inherent to CBCT seem to influence the values of density and the influence of FOV volume has not been completely elucidated. The aim of this study was to determine the effects of FOV size on density values in large-volume CBCT and MSCT images. A phantom made up of 3 cylinders containing distilled water, plaster and motor oil was constructed and inserted into an acrylic cylinder filled with distilled water. The phantom was scanned with a CBCT and MSCT device using 3 FOV sizes. Density of each material was evaluated in 40 regions of interest. In CBCT exams there was significant difference between the density values of different FOVs for the 3 materials. In the MSCT there was significant difference only for the oil. A significant correlation between CBCT and MSCT exams for the plaster in all of the FOVs was obtained. The water did not show significant correlation between CBCT and MSCT exams with the FOVs under study. The oil was not correlated in 8 x 8mm FOV and a low correlation of the FOVs 16 x 8mm and 16 x 13mm. The density values determined in CBCT images showed significant interference by varying the size of the FOV. The density values obtained in MSCT examinations showed a statistically significant difference only for oil. |
Keywords: | Densidade Tomografia Tomografia computadorizada de feixe cônico Density Tomography Cone-beam computed tomography |
CNPq: | CNPQ::CIENCIAS DA SAUDE |
Language: | por |
Country: | Brasil |
Publisher: | Universidade Federal de Juiz de Fora (UFJF) |
Institution Initials: | UFJF |
Department: | Faculdade de Medicina |
Program: | Programa de Pós-graduação em Saúde Brasileira |
Access Type: | Acesso Aberto |
URI: | https://repositorio.ufjf.br/jspui/handle/ufjf/5426 |
Issue Date: | 29-Oct-2013 |
Appears in Collections: | Doutorado em Saúde (Teses) |
Items in DSpace are protected by Creative Commons licenses, with all rights reserved, unless otherwise indicated.