Please use this identifier to cite or link to this item: https://repositorio.ufjf.br/jspui/handle/ufjf/3806
Files in This Item:
File Description SizeFormat 
marcosrodriguesfacchinicerqueira.pdf6.02 MBAdobe PDFThumbnail
View/Open
Type: Tese
Title: Construção, caracterização e aplicação analítica de microdispositivos enzimáticos
Author: Cerqueira, Marcos Rodrigues Facchini
First Advisor: Matos, Renato Camargo
Co-Advisor: Angnes, Lúcio
Referee Member: Lowinsohn, Denise
Referee Member: Silva, Julio Cesar Jose da
Resumo: O foco deste trabalho foi o desenvolvimento e aplicação de microreatores enzimáticos, visando sua aplicação em sistemas de análise por injeção em fluxo. Em cima disso, dois substratos poliméricos foram utilizados para a avaliação de imobilização enzimática: um à base de poli (metil metacrilato) (PMMA) e outro em uma resina do éter diglicídico do bisfenol-A (BADGE). Uma impressora à laser de CO2 foi utilizada para confeccionar os dispositivos nas dimensões desejadas. Para o sucesso da imobilização, os sistemas foram previamente tratados com polietilenoimina (PEI) visando a introdução de grupamentos funcionais reativos na superfície dos materiais de partida. Num primeiro estudo, baseado na modificação de PMMA, a ativação do material foi conseguida após tratamento dos microcanais com PEI em meio de dimetilsulfóxido (DMSO). Já no segundo caso o tratamento com PEI envolveu a simples mistura mecânica dos materiais, objetivando a cura da resina empregada. Após a ativação dos materiais com PEI, as enzimas foram imobilizadas após passagem de uma mistura de glutaraldeído (um agente espaçador) e as enzimas. Dentre as enzimas estudadas estão a glicose oxidase (GOx), a ascorbato-oxidase (AAO), a catalase (CAT), a glutamato dehidrogenase (GDH), além de um sistema híbrido baseado na imobilização simultânea das enzimas glicose oxidase (GOx) e horseradish peroxidase (HPR). A caracterização dos sistemas desenvolvidos foi feita primordialmente por meio da espectroscopia Raman. Além disso, a aplicação de alguns dos sistemas frente a amostras reais e o cálculo de parâmetros cinéticos e operacionais dos microreatores confeccionados foram reralizados. Essas avaliações foram feitas baseadas em sistemas de detecção desenvolvidos no laboratório por técnicas eletroquímicas e por espectroscopia no visível. Como grande benefício dos sistemas desenvolvidos, podem ser destacados a velocidade e a simplicidade de implementação do processo de imobilização e operação.
Abstract: The focus of this work is the development and application of enzymatic microreactors aiming their application through flow injection analysis systems. On top of that, two polymeric substrates were used for the evaluation of enzyme immobilization: one based on poly (methyl methacrylate) (PMMA) and another baed on a bisphenol-A diglycidyl ether resin (BADGE). A CO2 laser printer was used to fabricate the devices at the desired dimensions. For the success of the immobilization systems have been pretreated with polyethyleneimine (PEI) in order to introduce reactive functional groups on the surface of the starting materials. In a first study, based on PMMA modification, the activation of the material was achieved after treating microchannels with PEI in dimethylsulfoxide (DMSO). In the second case, treatment with PEI involved simply a mechanical mixture of the two materials, in order to cure the resin. After activation of materials with PEI, the enzymes were immobilized after passage of a mixture of glutaraldehyde (a spacer agent) and enzymes. Among the enzymes studied are glucose oxidase (GOx), ascorbate oxidase (AAO), catalase (CAT), dehydrogenase glutamate (GDH), and a hybrid system based on the simultaneous immobilization of the enzymes glucose oxidase (GOx) and horseradish peroxidase (HPR). The characterization of the developed systems was primarily done by Raman spectroscopy. Moreover, application of some of the proposed systems to real samples and calculation of kinetic and operational parameters are presented during the study. These evaluations were made with detection systems based on electrochemical and visible spectroscopy techniques, all developed at the laboratory. One great benefit of the developed systems, are the speed and simplicity of implementation the immobilization process and operation of the devices.
Keywords: Análise por injeção em fluxo
Imobilização enzimática
Microreator
Poli (metil metacrilato)
Resina do éter diglicídico do bisfenol-A
Polietilenoimina
Flow injection analysis
Enzymes immobilization
Microreactor
Poly(methylmethacrylate)
Bisphenol-A diglycidyl ether resin
Polyethyleneimine
CNPq: CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
Language: por
Country: Brasil
Publisher: Universidade Federal de Juiz de Fora (UFJF)
Institution Initials: UFJF
Department: ICE – Instituto de Ciências Exatas
Program: Programa de Pós-graduação em Química
Access Type: Acesso Aberto
URI: https://repositorio.ufjf.br/jspui/handle/ufjf/3806
Issue Date: 9-Sep-2016
Appears in Collections:Doutorado em Química (Teses)



Items in DSpace are protected by Creative Commons licenses, with all rights reserved, unless otherwise indicated.