https://repositorio.ufjf.br/jspui/handle/ufjf/16546
File | Description | Size | Format | |
---|---|---|---|---|
sumayakarlafarianeves.pdf | 3.06 MB | Adobe PDF | ![]() View/Open |
Type: | Dissertação |
Title: | Avaliação da atividade estrogênica em efluente sanitário bruto e tratado em uma estação de tratamento com sistema de lodos ativados com aeração prolongada |
Author: | Neves, Sumáya Karla Faria |
First Advisor: | Pereira, Renata de Oliveira |
Co-Advisor: | Bottrel, Sue Ellen Costa |
Referee Member: | Bil, Daniele Maia |
Referee Member: | Dias, Edgard Henrique Oliveira |
Resumo: | Os desreguladores endócrinos são compostos capazes de causar efeitos danosos à saúde, podendo afetar no crescimento, desenvolvimento, reprodução e comportamento de seres vivos. Esses compostos estão presentes nos efluentes domésticos, em sua maioria na forma de composto estrogênicos. O tratamento convencional de efluentes domésticos não objetiva a remoção de tais substâncias, e por consequência elas atingem os corpos hídricos. Sendo assim, o objetivo deste trabalho foi determinar a atividade estrogênica de efluente sanitário bruto e tratado, de uma estação de tratamento de esgotos (ETE) com sistema de lodos ativados por aeração prolongada. O efluente sanitário foi caracterizado de maio de 2019 a junho de 2022, quanto aos parâmetros físico-químicos e em relação a atividade estrogênica da fase líquida pelo ensaio in vitro Yeast Estrogen Screen, reportado em nanogramas equivalente de 17β-estradiol por litro (ngEQ-E2.L-1). A ETE alcançou eficiências de remoção de DQO, SST e N-NH3, de 85%, 71% e 46%, por ordem. A ETE conseguiu atender aos padrões da Resolução COPAM-CERH nº 8/2022, com exceção do N-NH3, que superou o valor máximo permitido em 57% das coletas. 85% das amostras de efluente bruto apresentaram atividade estrogênica, enquanto as de efluente tratado, 50%. A atividade estrogênica no efluente bruto variou entre menor que o limite de detecção (LD) e 543,90 ng EQ-E2.L-1 e no efluente tratado entre <LD e 95,48 ng-EQ-E2.L-1, apresentando desvio significativo entre as amostras. O CE50 mediano foi de 84,11 ± 172,29 ng.L-1 e o LD e LQ de 0,15 ± 0,05 e 0,44 ± 0,14 ngEQ-E2.L-1, respectivamente. A recuperação da amostra dopada com E2 foi de aproximadamente 84%. A remoção média de estrogenicidade foi de 86%, condizente com o esperado para sistemas de LA e suas variantes. Porém, as concentrações estimadas no corpo receptor após o lançamento do efluente tratado foram entre 0,0005 e 0,43 ngEQ-E2.L-1. A concentração máxima, está acima dos valores considerados como potenciais causadores de efeitos adversos ao ecossistema aquático. Portanto, conclui-se que é necessário a adoção de estratégias como o uso racional de compostos estrogênicos para minimar as suas concentrações no esgoto, bem como a realização de mais pesquisas que contribuam para sua inclusão como parâmetros de monitoramento de águas residuárias, com o objetivo de fomentar a adoção de estratégias e de novas tecnologias que objetivem aumentar a sua remoção nas ETEs. |
Abstract: | Endocrine disruptors are compounds capable of causing harmful effects on health and can affect the growth, development, reproduction and behavior of living beings. These compounds are present in domestic effluents, mostly in the form of estrogenic compounds. Conventional treatment of domestic effluents does not objectively remove such substances, and consequently they affect water bodies. Therefore, the objective of this work was to determine the estrogenic activity of raw and treated sanitary effluent from a sewage treatment plant (STP) with a sludge system activated by prolonged aeration. The sanitary effluent was characterized from May 2019 to June 2022, in terms of physical-chemical parameters in relation to the physicochemical parameters and the estrogenic activity of the liquid phase by the in vitro assay, reported in nanograms equivalent of 17β-estradiol (ngEQ-E2. L-1). The STP achieved COD, TSS and N-NH3 removal efficiencies of 85%, 71% and 46%, in order. The STP managed to meet the standards of COPAM-CERH Resolution nº 8/2022, with the exception of N-NH3, which exceeded the maximum value allowed in 57% of collections. 85% of the raw effluent samples had estrogenic activity, while 50% of the treated effluent. Estrogenic activity in raw effluent varies between <LD and 543.90 ng-EQ-E2.L-1 and in treated effluent between <LD and 95.48 ng-EQ-E2.L-1, showing significant deviation between samples. The median EC50 was 84.11 ± 172.29 ng.L-1 and the LD and LQ were 0.15 ± 0.05 and 0.44 ± 0.14 ngEQ-E2.L-1, respectively. The recovery of the E2-doped sample was approximately 84%. The average estrogenicity removal was 86%, consistent with what is expected for LA systems and their variants. However, the estimated estimates in the receiving body after the discharge of the treated effluent were between 0.0005 and 0.43 ngEQ-E2.L-1. The maximum concentration is above values considered to potentially cause adverse effects on aquatic biodiversity. Therefore, it is concluded that it is necessary to adopt strategies such as the rational use of estrogenic compounds to minimize their concentrations in sewage, as well as to carry out more research that contributes to their inclusion as wastewater monitoring parameters, with the aim of encourage the adoption of strategies and new technologies that aim to increase their removal in STPs. |
Keywords: | Ensaio YES (Yeast estrogen screen) Desreguladores endócrinos Esgoto doméstico Tratamento de esgoto Hormônios YES assay (Yeast estrogen screen) Endocrine disruptors Domestic sewage Sewage treatment Hormones |
CNPq: | CNPQ::ENGENHARIAS |
Language: | por |
Country: | Brasil |
Publisher: | Universidade Federal de Juiz de Fora (UFJF) |
Institution Initials: | UFJF |
Department: | Faculdade de Engenharia |
Program: | Programa de Pós-graduação em Engenharia Civil (PEC) |
Access Type: | Acesso Aberto Attribution-NonCommercial-NoDerivs 3.0 Brazil |
Creative Commons License: | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ |
URI: | https://repositorio.ufjf.br/jspui/handle/ufjf/16546 |
Issue Date: | 19-Sep-2023 |
Appears in Collections: | Mestrado em Engenharia Civil (Dissertações) |
This item is licensed under a Creative Commons License