Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufjf.br/jspui/handle/ufjf/15177
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
tauanarezendelopesmacarioferreira.pdf749.13 kBAdobe PDFVista previa
Visualizar/Abrir
Clase: Dissertação
Título : Os tamanhos do FOV e do voxel influenciam na avaliação do istmo de molares inferiores? Um estudo em TCFC
Autor(es): Ferreira, Tauana Rezende Lopes Macário
Orientador: Junqueira, Rafael Binato
Miembros Examinadores: Lemos, Cleidiel Aparecido Araujo
Miembros Examinadores: Vasconcelos, Rafaela Andrade de
Resumo: Este estudo analisou, por meio de exames de tomografia computadorizada de feixe cônico (TCFC), se o tamanho do campo de visão (FOV) e do voxel influenciam na avaliação de istmos em molares inferiores. Quarenta molares inferiores humanos foram submetidos à micro tomografia computadorizada para obtenção do padrãoouro. Em seguida, foram tomografados (ProMax® 3D Max) de acordo com sete protocolos de aquisição, variando-se os tamanhos de FOV (10 x 5,5 cm e 5 x 5,5 cm) e voxel (0,400 mm, 0,200 mm, 0,100 mm, e 0,075 mm). Três avaliadores classificaram a presença e o tipo de istmo, com base em uma escala de cinco pontos. Para comparação da frequência da detecção de istmo em cada protocolo com o padrãoouro, foi realizado o teste qui-quadrado. Foram calculados os valores de sensibilidade, especificidade e acurácia para cada protocolo de aquisição. A concordância intra e interexaminador foi verificada através do teste Kappa e variou de substancial a quase perfeita. Verificou-se que a presença de istmos foi subestimada, principalmente quando se utilizou voxel de 0,400 mm, independentemente do FOV utilizado. O protocolo com FOV 10 x 5,5 cm e voxel 0,200 mm apresentou os maiores valores de sensibilidade e acurácia e os menores valores de especificidade. Ao se compararem todos os valores de acurácia, o protocolo 2 (maior FOV) foi superior aos protocolos 4, 5 e 7. Concluiu-se que, independentemente do FOV, o valor do voxel não influenciou na avaliação de istmos em molares inferiores. A escolha do protocolo mais adequado dependerá das particularidades de cada situação clínica.
Resumen : Introduction: This study analyzed, through cone-beam computed tomography (CBCT) scans, whether the size of the field of view (FOV) and voxel influence the evaluation of isthmuses in mandibular molars. Methods: Forty human mandibular molars were submitted to microcomputed tomography to obtain the gold standard. Then, they were scanned (ProMax® 3D Max) using seven acquisition protocols, varying in FOV size (10 x 5.5 cm and 5 x 5.5 cm) and voxel (0.400 mm, 0.200 mm, 0.100 mm and 0.075 mm). Two examiners classified the presence and type of isthmus on a five-point scale. To compare the frequency of isthmus detection in each protocol with the gold standard, the chi-square test was conducted. Sensitivity, specificity and accuracy values were calculated for each protocol. Results: Intra- and inter-examiner agreement was verified using the weighted Kappa test and ranged from substantial to almost perfect. The presence of isthmuses was underestimated, especially with a 0.400-mm voxel, regardless of the FOV used. The protocol with 10 x 5.5-cm FOV and 0.200-mm voxel presented the greatest sensitivity and accuracy and the lowest specificity values. Upon comparing all accuracy values, protocol 2 (larger FOV) was better than protocols 4, 5 and 7. Conclusion: Regardless of FOV, the voxel size did not influence the evaluation of isthmuses in mandibular molars. The choice of the most appropriate protocol will depend on each clinical situation’ particularities.
Palabras clave : Anatomia radicular
Diagnóstico
Endodontia
Tomografia computadorizada de feixe cônico
Voxel
FOV
Istmo
Root anatomy
Diagnosis
Endodontics
Cone-beam computed tomography
Isthmus
CNPq: CNPQ::CIENCIAS DA SAUDE
Idioma: por
País: Brasil
Editorial : Universidade Federal de Juiz de Fora (UFJF)
Sigla de la Instituición: UFJF
Departamento: ICV - Instituto de Ciências da Vida
Programa: Mestrado Acadêmico em Ciências Aplicadas à Saúde
Clase de Acesso: Acesso Aberto
Attribution-NonCommercial 3.0 Brazil
Licenças Creative Commons: http://creativecommons.org/licenses/by-nc/3.0/br/
URI : https://repositorio.ufjf.br/jspui/handle/ufjf/15177
Fecha de publicación : 28-dic-2022
Aparece en las colecciones: Mestrado Acadêmico em Ciências Aplicadas à Saúde



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons