https://repositorio.ufjf.br/jspui/handle/ufjf/8577
File | Description | Size | Format | |
---|---|---|---|---|
Densidade mineral óssea de sítios.pdf | 485.87 kB | Adobe PDF | View/Open |
Type: | Artigo de Periódico |
Title: | Densidade mineral óssea de sítios específicos da maxila para a inserção de mini-implantes |
Other Titles: | Bone mineral density of specific maxillary sites for mini-implants insertion |
Author: | Santiago, Rodrigo César Cerrone Júnior, Giovanni Vitral, Robert Willer Farinazzo |
Resumo: | OBJETIVOS: avaliar a Densidade Mineral Óssea (DMO) de sítios específicos na maxila, por meio da Tomografia Computadorizada (TC) Multi-Slice. METODOLOGIA: foram realizadas 15 TC Multi-Slice da maxila para a avaliação da densidade mineral óssea de 30 regiões de interesse entre os segundos pré-molares e primeiros molares – 15 do lado direito e 15 do lado esquerdo – de 15 indivíduos (7 homens e 8 mulheres, com idade média de 21 anos) a serem submetidos ao tratamento ortodôntico, com mini-implantes como unidades de ancoragem. RESULTADOS: o resultado do teste t para observações pareadas revelou uma diferença estatisticamente significativa, quando os lados direito e esquerdo foram comparados (p < 0,05). CONCLUSÃO: a média dos valores obtidos para a DMO encontrou-se próxima ao valor máximo de uma escala considerada normal para a região posterior da maxila, podendo, assim, ser considerada essa uma área segura em termos de qualidade óssea para a inserção de mini-implantes. |
Abstract: | AIM: To assess the Bone Mineral Density (BMD) of specific maxillary sites, through multi-slice CT, investigating the possible correlation between different BMD levels and mini-implant stability. METHODS: Scans were obtained from 30 regions of interest (ROI), 15 on the right side and 15 on the left side, of 15 individuals (7 males and 8 females with 21 years old mean age) about to start orthodontic treatment with mini-implants as anchorage units. BMD values were normally distributed. Paired t-test results showed statistically significant differences when the two sides were compared (p < 0.05). However, the mean of BMD values was close to the maximum value of a considered normal scale for maxillary posterior region, indicating that this is a safe area in terms of bone quality for mini-implants insertion. |
Keywords: | TC Multi-Slice Densidade óssea Maxila Multi-Slice CT Bone density Maxillary |
CNPq: | - |
Language: | por |
Country: | Brasil |
Publisher: | - |
Institution Initials: | - |
Access Type: | Acesso Aberto |
DOI: | http://dx.doi.org/10.1590/S1415-54192009000300010 |
URI: | https://repositorio.ufjf.br/jspui/handle/ufjf/8577 |
Issue Date: | Jan-2009 |
Appears in Collections: | Artigos de Periódicos |
Items in DSpace are protected by Creative Commons licenses, with all rights reserved, unless otherwise indicated.