Use este identificador para citar ou linkar para este item: https://repositorio.ufjf.br/jspui/handle/ufjf/7226
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
annelisafarahsilvapaesleme.pdf3.63 MBAdobe PDFThumbnail
Visualizar/Abrir
Tipo: Tese
Título: Revestimento antibiofilme para superfícies de dispositivos médico-hospitalares
Autor(es): Leme, Annelisa Farah Silva Paes
Primeiro Orientador: Raposo, Nádia Rezende Barbosa
Membro da banca: Silva, Frederico Pittella
Membro da banca: Brandão, Marcos Antônio Fernandes
Membro da banca: Vieira, Rita de Cássia Padula Alves
Membro da banca: Dutra, Rafael Cypriano
Resumo: Biofilmes associados a dispositivos médicos são responsáveis por 85% das infecções de corrente sanguínea relacionadas a catéteres (ICSRC). O objetivo deste trabalho foi testar duas formulações, como revestimento para catéteres venosos centrais (CVC), as quais tiveram a eficácia antimicrobiana e antiaderente avaliadas in vitro e a eficácia e biocompatibilidade, in vivo. A atividade antimicrobiana foi determinada por método turbidimétrico e a concentração inibitória mínima (CIM) foi estabelecida. A microscopia eletrônica de varredura (MEV) avaliou a propriedade antiaderente dos CVC revestidos com a formulação 1 (CVC-R1) e formulação 2 (CVC-R2), comparados aos não revestidos (CVC-NR). Implantes subcutâneos foram inseridos na área dorsal de ratos. O primeiro ensaio compreendeu análises hematológicas e microbiológicas (hemocultura e colonização das superfícies de CVC), a fim de avaliar a eficácia dos revestimentos. A biocompatibilidade foi avaliada no segundo ensaio pela observação das reações inflamatórias após 7 e 21 dias. Ambas formulações apresentaram atividade antimicrobiana frente a todas as cepas testadas. A desagregação do biofilme, com redução significativa da aderência microbiana, foi observada em ambos CVC revestidos. In vivo, foi observada maior eficácia antibiofilme de CVC-R2, com redução da colonização por Staphylococcus aureus ATCC 25923. As reações teciduais provocadas por CVC-R1 e CVC-R2 foram mais pronunciadas inicialmente, contudo, ao longo do experimento, se tornaram estatisticamente semelhantes às do CVC-NR. Ambas as formulações foram biocompatíveis, com maior velocidade de reparo tecidual no grupo CVC-R2. O uso de CVC- R1 e, especialmente de CVC-R2, pode diminuir a incidência de ICSRC. Acredita-se que CVC-R2 apresenta potencial para ser testado clinicamente.
Abstract: Device-associated biofilms are responsible for 85% of catheter-related bloodstream infections (CRBSI). The aim of this study was investigate two formulations, as central venous catheters (CVC) coating, which were submitted to in vitro evaluation of antimicrobial and anti-adherent efficacy and in vivo evaluation of efficacy and biocompatibility. The antimicrobial activity was assessed by turbidimetric method and the minimum inhibitory concentration (MIC) was determined. The scanning electron microscopy (SEM) was used to assess the anti-adherent property of CVC coated with formulation 1 (CVC-R1) and formulation 2 (CVC-R2), in comparison to uncoated CVC fragments (CVC-NR). Subcutaneous implants were inserted into the dorsal area of rats. The first assay consisted in hematological and microbiological analysis (hemoculture and CVC surfaces colonization) in order to evaluate the coatings effectiveness. The second assay evaluated the biocompatibility by the observation of inflammatory reactions after 7 and 21 days. Both formulations showed antimicrobial activity against all tested strains. The biofilm disaggregation, with reduction in microbial adherence, was noted in coated catheters. In vivo results showed greater antibiofilm efficacy of CVC-R2 since a reduction of Staphylococcus aureus ATCC 25923 colonization was observed. The tissue reactions of CVC-R1 and CVC-R2 groups were initially more pronounced, however, throughout the experiment, the histological parameters have become statistically similar those found in CVC-NR group. Both formulations were biocompatible and a higher speed of tissue repair in CVC-R2 group was noted. The use of CVC- R1, and especially of CVC-R2, may reduce the development of CRBSI, and thereby, CVC-R2 have potential to be clinically tested.
Palavras-chave: Aderência bacteriana
Biofilmes
Catéteres
Infecções relacionadas a catéter
Prevenção & controle
Bacterial adhesion
Biofilms
Catheters
Catheter-related infections
Prevention & control
CNPq: CNPQ::CIENCIAS BIOLOGICAS
Idioma: por
País: Brasil
Editor: Universidade Federal de Juiz de Fora (UFJF)
Sigla da Instituição: UFJF
Departamento: ICB – Instituto de Ciências Biológicas
Programa: Programa de Pós-graduação em Ciências Biológicas: Imunologia e Doenças Infecto-Parasitárias/Genética e Biotecnologia
Tipo de Acesso: Acesso Aberto
URI: https://repositorio.ufjf.br/jspui/handle/ufjf/7226
Data do documento: 14-Fev-2014
Aparece nas coleções:Doutorado em Ciências Biológicas - Imunologia e Doenças Infecto - Parasitárias/Genética e Biotecnologia (Teses)



Os itens no repositório estão protegidos por licenças Creative Commons, com todos os direitos reservados, salvo quando é indicado o contrário.