Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufjf.br/jspui/handle/ufjf/698
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
marciodecarvalhofilho.pdf1.28 MBAdobe PDFVista previa
Visualizar/Abrir
Clase: Dissertação
Título : Uma metodologia para análise de falhas em sistemas elétricos multifásicos
Autor(es): Carvalho Filho, Márcio de
Orientador: Araujo, Débora Rosana Ribeiro Penido
Co-orientador: Araujo, Leandro Ramos de
Miembros Examinadores: Costa, Vander Menengoy da
Miembros Examinadores: Oliveira, Leonardo Willer de
Resumo: Neste trabalho desenvolveu-se uma ferramenta para análise de falhas, sendo os modelos de diversos equipamentos do sistema elétrico considerados de forma detalhada, permitindo a análise multifásica do sistema, representando-o da maneira mais generalizada e realista possível. A metodologia desenvolvida para análise de falhas baseia-se no método de injeção de correntes a n condutores em coordenadas retangulares, onde utiliza-se o método de Newton-Raphson no processo de solução e todas as grandezas são definidas diretamente em coordenadas de fase. A modelagem de todo o sistema elétrico é realizada baseando-se em elementos que compõem as estruturas dos equipamentos em seus modelos, sendo que estes elementos podem estar conectados das mais diversas maneiras. As próprias condições de curto-circuito são modeladas por meio de elementos, conectados em diferentes configurações. Também a inclusão dos controles é feita de forma otimizada. Com a modelagem considerada, o sistema a ser solucionado é o estritamente necessário, e, portanto, a metodologia apresenta-se bastante eficiente. A metodologia também se mostra bastante flexível, pois é capaz de representar equipamentos com qualquer número de condutores nas mais diversas configurações, permitindo representar desequilíbrios, acoplamentos mútuos, sistemas de aterramento e cabos neutros explicitamente, e permitindo modelar diversos tipos de falhas, dentre outras características. Desta forma, a metodologia possibilita análises bastante completas, sendo que a representação do sistema pode ser feita com o nível de detalhe que for possível e desejável em cada situação. A ferramenta desenvolvida é bastante abrangente sendo capaz de simular sistemas equilibrados ou desequilibrados, radiais ou reticulados, diversos tipos de falhas (como curtos-circuitos em derivação, interno e simultâneo, ou abertura série), podendo ser aplicada em sistemas de transmissão, subtransmissão, distribuição, e industriais, inclusive de grande porte.
Resumen : In this work a tool for fault analysis was developed, and models of many electrical systems equipment were considered in detail, allowing the analysis of multiphase systems by representing it in a more general and realistic way possible. The methodology developed for fault analysis is based on the current injection method in rectangular coordinates, where the Newton-Raphson method is used in the solution process and all quantities are defined directly in phase coordinates. The modeling of the entire electrical system is made based on elements which assemble the structures of equipment in their models, and these elements can be connected in various ways. Even the short circuit conditions are modeled by elements connected in different configurations. Also the inclusion of controls is done optimally. With the considered modeling the system to be solved is the strictly necessary, and therefore, the method shows to be efficient. The methodology is also very flexible because it is able to represent equipments with any number of conductors in many different configurations, allowing the representation of imbalances, mutual couplings, groundings and neutral cables explicitly, and allowing to model various types of faults, among other features. Therefore, the methodology allows fairly complete analysis, and the representation of the system can be made with the level of detail that is possible and desirable in every situation. The tool developed is quite ample being able to simulate balanced or unbalanced, radial or meshed systems, various types of failures (such as shunt short circuits, internal faults, simultaneous fault, and series opening), it can be applied to the transmission, subtransmission, distribution and industrial systems, including large scale systems.
Palabras clave : Método de Injeção de Correntes
Sistemas de Distribuição Desequilibrados
Análise de Falhas
Falhas Internas
Current Injection Method
Unbalanced Distribution Systems
Fault Analysis
Internal Faults
CNPq: CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
Idioma: por
País: Brasil
Editorial : Universidade Federal de Juiz de Fora
Sigla de la Instituición: UFJF
Departamento: Faculdade de Engenharia
Programa: Programa de Pós-graduação em Engenharia Elétrica
Clase de Acesso: Acesso Aberto
URI : https://repositorio.ufjf.br/jspui/handle/ufjf/698
Fecha de publicación : 13-ago-2014
Aparece en las colecciones: Mestrado em Engenharia Elétrica (Dissertações)



Los ítems de DSpace están protegidos por licencias Creative Commons, con todos los derechos reservados, a menos que se indique lo contrario.