Please use this identifier to cite or link to this item: https://repositorio.ufjf.br/jspui/handle/ufjf/1991
Files in This Item:
File Description SizeFormat 
fernandoluizgoulartcruz.pdf3.24 MBAdobe PDFThumbnail
View/Open
Type: Dissertação
Title: Influência da orientação proximodistal do mini-implante ortodôntico, na distribuição de tensões: análise numérica
Other Titles: Influence of the mesio-distal direction of the miniscrew on stress distribution: numerical analysis
Author: Cruz, Fernando Luiz Goulart
First Advisor: Leite, Fabíola Pessôa Pereira
Co-Advisor: Bastos, Flávia de Souza
Referee Member: Pellizzer, Eduardo Piza
Referee Member: Toledo, Elson Magalhães
Resumo: O objetivo deste estudo foi avaliar pelo método de elementos finitos (MEF), a influência da orientação do Mini-implante Ortodôntico (MIO), em relação ao carregamento, na distribuição de tensões no tecido ósseo. Por meio da interface gráfica do programa de elementos finitos Abaqus/CAE, foram confeccionados modelos tridimensionais, correspondentes a um MIO, a uma seção do osso maxilar e dentes pré-molar e molar provenientes de cortes de tomografia computadorizada no formato Dicom. Todas as partes foram consideradas como seções sólidas e homogêneas, com propriedades isotrópicas e lineares-elásticas. Foi aplicada no MIO uma força de 2N, decomposta a 45º em duas componentes sobre o plano normal ao seu eixo longitudinal. Para a simulação numérica, o MIO foi instalado em nove orientações proximodistais diferentes. Uma instalação ortogonal à superfície vestibular (angulação de 0º), outras de -10º, -20º, -30º e -40º a favor da força aplicada e 10º, 20º, 30º e 40º contrários à força aplicada. Por meio do critério de von Mises e da análise das tensões principais observou-se que houve uma variação das tensões em função da orientação, sendo que a situação que ocorreu menor concentração para o osso cortical foi a de 0º, enquanto que a -20º e 20º ocorreram maiores concentrações. Conclui-se que houve influência da orientação proximodistal do MIO, em relação ao carregamento, na distribuição de tensões no tecido ósseo.
Abstract: The aim of this study was to evaluate, by finite element method (FEM), the influence of load direction on stress distribution in bone tissue around orthodontic miniscrew. By means of the graphic interface of Abaqus/CAE finite element program, tridimensional models were made, corresponding to a miniscrew, section of maxillary bone, premolar and molar teeth taken from computerized tomograph cuts in Dicom format. All parts were considered solid and homogeneous sections with isotropic and linear-elastic properties. A 2N force was applied on the miniscrew, decomposed in two components at 45º on the plane normal to its longitudinal axis. For numerical simulation, the miniscrew was placed in nine different mesio-distal directions. A placement orthogonal to the vestibular surface (angulation of 0º), others of -10º, -20º, -30º and -40º in favor of the force applied and 10º, 20º, 30º and 40º contrary to the force applied. By means of von Mises criteria and analysis of main stressed it was observed that there was a variation in stresses as a result of direction, and the most attenuating situation for the cortical bone was that of 0º, whereas at -20º and 20º higher stress concentrations occurred. It was concluded that there was influence of the mesio-distal direction of the miniscrew in relation to load, of stress distribution in bone tissue.
Keywords: Análise de elemento finito
Implante dentário
Procedimentos de ancoragem ortodôntica
Dental Implantation
Finite Element Analysis
Orthodontic Anchorage Procedures
CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::CLINICA ODONTOLOGICA
Language: por
Country: Brasil
Publisher: Universidade Federal de Juiz de Fora
Institution Initials: UFJF
Department: Faculdade de Odontologia
Program: Programa de Pós-graduação em Clínica Odontológica
Access Type: Acesso Aberto
URI: https://repositorio.ufjf.br/jspui/handle/ufjf/1991
Issue Date: 6-Mar-2012
Appears in Collections:Mestrado em Odontologia (Dissertações)



Items in DSpace are protected by Creative Commons licenses, with all rights reserved, unless otherwise indicated.