Please use this identifier to cite or link to this item: https://repositorio.ufjf.br/jspui/handle/ufjf/1772
Files in This Item:
File Description SizeFormat 
ricardosilvacampos.pdf8.33 MBAdobe PDFThumbnail
View/Open
Type: Tese
Title: Modelagem eletromecânica do coração com autômato celular e sistemas massa-mola
Author: Campos, Ricardo Silva
First Advisor: Santos, Rodrigo Weber dos
Co-Advisor: Lobosco, Marcelo
Co-Advisor: Rocha, Bernardo Martins
Referee Member: Alves, José Luis Drummond
Referee Member: Karam Filho, José
Referee Member: Silva, Rodrigo Luis de Souza da
Referee Member: Barra, Luis Paulo da Silva
Resumo: Este trabalho apresenta o simulador FisioPacer, que é um simulador que reproduz a propagação do pulso elétrico pelo tecido cardíaco e a sua deformação mecânica. Foi utilizado um autômato celular acoplado a um sistema massa-mola para que as simulações sejam realizadas rapidamente. Foi também utilizado um algoritmo genético para automaticamente determinar parâmetros do modelo de forma a reproduzir outros experimentos in silico e o comportamento de um ventrículo real. Com intuito de validar o modelo foram feitos setenta e dois experimentos e os resultados foram comparados com outro simulador robusto, baseado em equações diferenciais. As comparações mostraram que o FisioPacer reproduziu satisfatoriamente o comportamento do tecido, sendo até quinze mil vezes mais rápido. Além disto, foram simuladas as funcionalidades eletromecânicas de um ventrículo esquerdo a partir de dados de um paciente, obtidos via ressonância magnética.
Abstract: This work proposes a computational heart model named FisioPacer, which aims to reproduce the electrical pulse propagation over the cardiac tissue and its mechanical deformation. In order to perform fast simulations, it was used a cellular automaton coupled with a mass-spring system. A genetic algorithm was also used to automatically adjust model parameters, in order to reproduce in silico experiments and a real left ventricle behavior. For the model validation, seventy two experiments were performed and the results were compared to another robust simulator, based on partial differential equations. The comparisons showed that the FisioPacer simulator could reproduce cardiac tissue electromechanics, with up to 15000-fold improvement in computational time. Furthermore, a real patient left ventricle was simulated, with data obtained via MRI.
Keywords: Eletrofisiologia cardíaca
Modelagem computacional
Autômato celular
Sistema massa-mola
Cardiac electrophysiology
Computational modeling
Cellular automaton
Mass-spring system
CNPq: CNPQ::ENGENHARIAS
Language: por
Country: Brasil
Publisher: Universidade Federal de Juiz de Fora
Institution Initials: UFJF
Department: Faculdade de Engenharia
Program: Programa de Pós-graduação em Modelagem Computacional
Access Type: Acesso Aberto
URI: https://repositorio.ufjf.br/jspui/handle/ufjf/1772
Issue Date: 15-Feb-2016
Appears in Collections:Doutorado em Modelagem Computacional (Teses)
PROQUALI - Teses



Items in DSpace are protected by Creative Commons licenses, with all rights reserved, unless otherwise indicated.