Estimação de fasores harmônicos baseada em banco de filtros polifásicos: implementação em FPGA com processador embarcado

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Universidade Federal de Juiz de Fora (UFJF)

DOI

Abstract

The growing number of nonlinear loads and power electronics based sources makes the voltages and currents in the power grid move away from the ideal sinusoidal waveform, so it becomes important to estimate not only the fundamental component but also the harmonic components of the signal. This task becomes harder when the fundamental frequency deviates from its nominal value, since the phase error grows with the harmonic order. This work presents and implements a harmonic phasor estimation method for signals with varying frequency, made up of three stages: frequency estimation by zero crossing, smoothed by a Kalman filter; dynamic resampling of the signal by B-Spline interpolation in a Farrow structure; and harmonic extraction by a Flat-Top filter bank with polyphase decomposition, followed by an IDFT. Thanks to the resampling, the filter bank always works with the nominal number of samples per cycle and its coefficients do not need to be recomputed. The method was first developed as a reference model in Python and then implemented on two soft-core processors of the SAPHO platform, one for the interpolator and one for the filter bank, which communicate through FIFO memories and are coordinated by a state machine. During the implementation, some stages had to be adjusted because of the 32-bit arithmetic of the processor, such as the Kalman filter and the period calculation in the zero crossing estimator. The implementation was validated by functional simulation and compared with the reference model in tests based on the IEC/IEEE 60255-118-1 standard, with off-nominal frequency, frequency ramp and modulation. The frequency was estimated accurately in all tests. In the off-nominal case, the reference model stayed below the 1% TVE limit over the whole range evaluated, and the embedded implementation only exceeded this limit at the highest harmonic orders. The results showed that this difference comes mainly from the time misalignment between the signal and the frequency used in the phase correction, and not from the numerical precision of the filter bank. In the ramp test, on the other hand, the reference model itself exceeds the limit at the highest orders, which points to a limitation of the method under continuous frequency variation. Overall, the results show that the method is feasible on an embedded platform and indicate where it can still be improved.

Description

Citation

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwise noted, this item's license is described as Acesso Aberto