Análise do comportamento estrutural de perfis de aço formados a frio com enrijecedores na alma aplicados como terças
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
Cold-formed steel sections are widely used in roofing systems due to their high strength-toweight
ratio and ease of manufacturing. However, because of their thin-walled elements, these
members are more susceptible to instability phenomena, making the proper verification of their
load-carrying capacity and service performance essential. This study presents the structural
analysis of steel purlins from an actual roof structure, emphasizing the influence of intermediate
web stiffeners on the structural behavior of the sections. Initially, the load combinations for the
Serviceability Limit State (SLS) and Ultimate Limit State (ULS) were established, and the
vertical displacements and bending moments were obtained using the FTOOL software.
Subsequently, the sections were designed using the Direct Strength Method (DSM), according
to ABNT NBR 14762:2010, with the aid of the CUFSM software to determine the elastic
critical stresses and the resistant moments associated with global, local, and distortional
buckling modes. A comparative analysis was then carried out among different cold-formed steel
sections, considering both structural performance and steel consumption. The results showed
that intermediate web stiffeners significantly increase the resistance to local buckling, allowing
the use of thinner and lighter sections. It was also observed that sections with lapped
connections over the supports provide greater structural efficiency, enabling the adoption of
members with lower linear weight. Among the analyzed sections, the ZAE 280 section
presented the lowest total steel consumption under the conditions evaluated, although the
difference compared with the Z90 and stiffened U sections was relatively small due to the
additional length required by the lap connections. It is concluded that the selection of the most
appropriate section should consider not only strength and stability but also serviceability
performance, constructability, and economic feasibility.