Análise da radiopacidade de novos cimentos biocerâmicos endodônticos
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora - Campus Avançado de Governador Valadares
DOI
Abstract
The present study aimed to evaluate the radiopacity of new endodontic
bioceramic cements and compare it with that of dental structures. The research
evaluated the radiopacity of the following cements: MTA Repair HP, MTA Angelus®,
Bio-C® Repair, MTA Fillapex, Bio-C® Sealer, BiodentineTM, CIMMO HD and CIMMO
HP. Five specimens (4 mm in diameter x 1 mm in thickness) were made from each of
the materials, using a split Teflon matrix. Radiographs were taken using a semi-direct
digital acquisition system using photostimulable phosphor plates (PSP). The following
were positioned on the PSP: a test body of each material, three human tooth cuts, and
an aluminum scale with 99.9% purity, with 11 steps of 1 mm thickness. Each set was
x-rayed five times. Relative radiographic density (RRD) was collected using histogram
analysis in image processing software. The descriptive analysis and normality of the
data were verified using the Shapiro-Wilk test, which indicated normal distribution
(p>0.05). Pearson correlation and linear regression analyzes were performed to
convert DRR values into millimeters of AL (mmAL), and one-way ANOVA, with Tukey
post-hoc to compare values. BIO-C Repair showed the highest radiopacity (5.76
mmAl), followed by BIO-C Sealer (5.64 mmAL) and MTA Angelus (4.96 mmAL)
(p<0.05). While CIMMO HD (0.69 mmAL) and Biodentine (1.74 mmAL) showed the
lowest values (p<0.05). Only CIMMO HD was similar to root dentin (0.16 mmAL)
(p>0.05). BIO-C Repair, BIO-C Sealer, CIMMO HP (3.19 mmAL) and MTA Angelus
exhibited higher values than enamel (2.01 mmAL) (p<0.05). On the other hand,
Biodentine, MTA Fillapex (2.59 mmAL) and MTA Repair HP (3.40 mmAL) were
statistically similar to enamel (p>0.05). Biodentine, CIMMO HD and MTA Fillapex were
the only ones that did not meet the minimum radiopacity required by ISO (2012) and
ANSI/ADA n.57 (2008) standards. It can be concluded that radiopacity varied greatly
between the cements tested and, considering only this physical property, Biodentine,
CIMMO HD and MTA Fillapex bioceramics do not meet the appropriate requirements
for clinical applications.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto