Análise da radiopacidade de novos cimentos biocerâmicos endodônticos

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Universidade Federal de Juiz de Fora - Campus Avançado de Governador Valadares

DOI

Abstract

The present study aimed to evaluate the radiopacity of new endodontic bioceramic cements and compare it with that of dental structures. The research evaluated the radiopacity of the following cements: MTA Repair HP, MTA Angelus®, Bio-C® Repair, MTA Fillapex, Bio-C® Sealer, BiodentineTM, CIMMO HD and CIMMO HP. Five specimens (4 mm in diameter x 1 mm in thickness) were made from each of the materials, using a split Teflon matrix. Radiographs were taken using a semi-direct digital acquisition system using photostimulable phosphor plates (PSP). The following were positioned on the PSP: a test body of each material, three human tooth cuts, and an aluminum scale with 99.9% purity, with 11 steps of 1 mm thickness. Each set was x-rayed five times. Relative radiographic density (RRD) was collected using histogram analysis in image processing software. The descriptive analysis and normality of the data were verified using the Shapiro-Wilk test, which indicated normal distribution (p>0.05). Pearson correlation and linear regression analyzes were performed to convert DRR values into millimeters of AL (mmAL), and one-way ANOVA, with Tukey post-hoc to compare values. BIO-C Repair showed the highest radiopacity (5.76 mmAl), followed by BIO-C Sealer (5.64 mmAL) and MTA Angelus (4.96 mmAL) (p<0.05). While CIMMO HD (0.69 mmAL) and Biodentine (1.74 mmAL) showed the lowest values (p<0.05). Only CIMMO HD was similar to root dentin (0.16 mmAL) (p>0.05). BIO-C Repair, BIO-C Sealer, CIMMO HP (3.19 mmAL) and MTA Angelus exhibited higher values than enamel (2.01 mmAL) (p<0.05). On the other hand, Biodentine, MTA Fillapex (2.59 mmAL) and MTA Repair HP (3.40 mmAL) were statistically similar to enamel (p>0.05). Biodentine, CIMMO HD and MTA Fillapex were the only ones that did not meet the minimum radiopacity required by ISO (2012) and ANSI/ADA n.57 (2008) standards. It can be concluded that radiopacity varied greatly between the cements tested and, considering only this physical property, Biodentine, CIMMO HD and MTA Fillapex bioceramics do not meet the appropriate requirements for clinical applications.

Description

Citation

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwise noted, this item's license is described as Acesso Aberto