O comportamento mecânico de uma tela ortodôntica para contenções periodontais: um estudo em modelos experimentais
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
The present study aimed to evaluate the mechanical behavior of the orthodontic mesh for
base, mesh 80, wire ø0.12 mm, for a possible indication in dental retention. The objective
was also to evaluate the swine model as a test specimen for studies in the area of
dentistry. Methods: Forty-five periodontal retainers were made in swine teeth, subjected
to resistance test to mechanical shear force in E-mic machine and, subsequently,
classified according to the Adhesive Remnant Index. Results: The use of swine models
proved to be adequate for carrying out the study. The test specimens presented a
maximum average shear strength of 317 MPa and a median of 295 MPa. 95.5% of the
retainers studied presented an adhesive remnant index score of 2 or 3, therefore, they
are capable of complete repair, even after having been subjected to the force test.
Conclusions: The use of a swine mandibular segment proved to be effective for carrying
out the study and the mechanical behavior of the mesh used is compatible with a possible
indication for dental retention.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto