O comportamento mecânico de uma tela ortodôntica para contenções periodontais: um estudo em modelos experimentais

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Universidade Federal de Juiz de Fora (UFJF)

DOI

Abstract

The present study aimed to evaluate the mechanical behavior of the orthodontic mesh for base, mesh 80, wire ø0.12 mm, for a possible indication in dental retention. The objective was also to evaluate the swine model as a test specimen for studies in the area of dentistry. Methods: Forty-five periodontal retainers were made in swine teeth, subjected to resistance test to mechanical shear force in E-mic machine and, subsequently, classified according to the Adhesive Remnant Index. Results: The use of swine models proved to be adequate for carrying out the study. The test specimens presented a maximum average shear strength of 317 MPa and a median of 295 MPa. 95.5% of the retainers studied presented an adhesive remnant index score of 2 or 3, therefore, they are capable of complete repair, even after having been subjected to the force test. Conclusions: The use of a swine mandibular segment proved to be effective for carrying out the study and the mechanical behavior of the mesh used is compatible with a possible indication for dental retention.

Description

Citation

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwise noted, this item's license is described as Acesso Aberto