Determinação de Al, Cr, Fe, Mn, Pb e Zn em amostras de óleo lubrificante automotivo usado por espectrometria de absorção atômica após extração por quebra de emulsão
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
The presence of metallic species in used lubricating oil (LO) is an important indicator of
the wearing process undergone by engines, and can lead to environmental contamination
through vehicle exhaust system. Therefore, in this work two methods of sample
preparation for the determination of Al, Cr, Fe, Mn, Pb and Zn in used LO samples by
Flame Atomic Absorption Spectrometry (F AAS) were described. The first method is the
acid digestion of samples on hot plate, using H2SO4, HNO3 and H2O2 as oxidizing agents,
where the accuracy of the method represented by RSD values is minor than 10%,
and the recovery test of the analytes ranged from 81.7 to 109.1%. However, the limits of
quantification for this method were 33.3 mgKg-1 (Al), 16.0 mgKg-1 (Cr), 8.3 mgKg-1 (Fe),
6.7 mgKg-1 (Mn), 37.2 mgKg-1 (Pb) and 3.8 mgKg-1 (Zn), which makes this method not
suitable for the termination of Al, Cr, Mn and Pb by F AAS on used LO samples. The
second method was the extraction of the analytes by emulsion breaking (EBE), which
consisted in breaking the water-in-oil emulsion formed when mixing the sample with an
acid solution of Triton X-114 (extraction solution). The parameters optimized for the EBE
process were: the composition and volume of the extraction solution, the emulsion
breaking process, the agitation time and the use of an organic solvent that is used to
decrease sample viscosity. The results obtained were: 1.5 mL of extraction solution (6.0%
w/v Triton X-114, 2.1 molL-1 HNO3), emulsion breaking by heating at 80°C, 1.0 minute
stirring and n-hexane as the organic solvent. The limits of quantification found for the
EBE method were 0.700 mgkg-1 (Al), 0.351 mgkg-1 (Cr), 0.499 mgkg-1 (Fe), 0.102 mgkg-1
(Mn), 0.227 mg kg-1 (Pb) and 0.038 mgKg-1 (Zn). The method was applied to four
different samples, where the content of the analytes followed the order Zn > Fe > Al >
Mn > Pb > Cr. The similar tendency found for the analytes concentration on the different
samples can indicate that the accumulation of those metallic species in LO samples comes
from the same kind of metal alloys used in car engines.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Rights and licensing
Acesso Aberto