Limpeza e modelagem de canais ovais após preparo químico-mecânico utilizando três sistemas de instrumentação e irrigação com hipoclorito de sódio: estudo correlativo usando microtomografia computadorizada e histologia
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Estácio de Sá
DOI
Abstract
Purpose: The present study evaluated the cleaning and shaping ability of three
instrumentation systems in oval canals of vital teeth using a correlative
analytical approach.
Materials and methods: Distal roots of oval canals with pulp vitality were
scanned by computed microtomography (micro-CT) for sample selection and
distribution into three experimental groups according to the instrument to be
evaluated: self-adjusting files (SAF), TRUShape and XP-endo Shaper. In all
groups, the irrigant was sodium hypochlorite (5.25%) heated at 37°C. After rescanning
by micro-CT, the untouched walls were measured and then
histologically evaluated for the amount of pulp remaining in the root thirds.
Results: SAF was more effective in touching the walls at 4 mm from the apex,
presenting a significantly lower value of untouched walls when compared to XPendo
Shaper (P <0.049). However, it was not possible to verify significant
differences in the full canal length between groups. The amount of pulp
remnants also did not differ between instruments in the canal thirds. There was
no significant correlation between untouched areas and pulp remnants for any
instrument.
Conclusion: There was no significant difference in the amount of untouched
walls between instruments, except between SAF and XP-endo Shaper in the
apical 4 mm. There was no significant difference in the cleaning ability either.
The non-correlation between untouched walls and pulp remnants indicates the
effectiveness of different instruments and sodium hypochlorite irrigation in the
elimination of soft tissue from unprepared walls.