Non-Adaptive and Adaptive Coupling Circuits for Power Line Communication System
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
This work outlines a comprehensive review of PLC coupling circuits, which are required
for narrowband and broadband PLC transceivers. Prevailing issues that protract
the design of couplers and consequently subtended the inventions of different types
of couplers are clearly described. Also, it provides a useful classification of PLC
couplers based on the type of physical couplings, voltage levels, frequency bandwidth,
propagation modes and a number of connections. Next, the focus is on the design of
non-adaptive capacitive, SISO and low-voltage (LV) PLC coupling circuits for both
broadband and narrowband applications. The narrowband cover the frequency band
9 kHz-500 kHz, while broadband frequency bands are 1.7-50MHz, 1.7-100MHz and 1.7-
500 MHz. Moreover, it discusses the specification and design of the prototypes of the
PLC coupling circuits measuring their scattering parameters. The access impedance
of Brazilian in-home, broadband and low-voltage electric power grid in the frequency
band 2-500 MHz is taken into account. Based on the use of a measurement setup a
large measurement campaign that was carried out in several facilities in three different
Brazilian cities is discussed. Also, a procedure to obtain a statistical model of the access
impedance in the aforementioned broadband frequency is outlined. Based on a number
of measured access impedances and well-known criteria for choosing statistical models,
two distributions to model the resistance and reactance components of the access
impedance are suggested. Due to the fact that the parameters of such models change
with the frequency and the access impedance is a random process in the frequency
domain, a simple and effective model to generate samples function of such random
process, which takes into account the suggested distributions, is addressed. Finally,
adaptive capacitive, SISO and LV PLC coupling circuits are proposed for broadband
power line communication. These adaptive coupling circuits use three different analog
low-pass filter for impedance matching. This filter is an array of analog low-pass
irregular filters that separate the input and output signal into three analog low-pass
filters, each one matching the impedance between the electric power grid and PLC
transceiver. The input impedance of each filter has a different impedance value, chosen
according to the impedance of the measurement campaign, and the output impedance
is fixed in 50 Ω for all analog low-pass filter. The choice of the analog filter that provides
better impedance matching to the electrical power grid is obtained by a microcontroller,
which through an analog-to-digital converter (ADC), measure the voltage provided
by a circuit that measures the power of the signals injected into the PLC coupling
circuit by the PLC transceivers. The power is continuously measured by an ADC
of the microcontroller which chooses which analog filter provides the best impedance
matching with the electric power grid and switches the analog filters through an analog
switcher connecting the PLC transceivers to the electric power grid through the PLC
coupling circuit. In addition, the measured values of the scattering parameter S11 show
that the best impedance matching occurs when the resistive impedance component of
the access impedance is between 50 Ω and 100 Ω . For the scattering parameter S12
it has been found that the attenuation increases as the frequency increases because of
the inductive behavior of the electric power grid.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Rights and licensing
Acesso Aberto