Influência da osseodensificação e da macrogeometria dos implantes na estabilidade primária e na microarquitetura óssea peri-implantar: estudo experimental
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
Primary stability is a crucial factor for successful osseointegration and is
influenced by bone density, drilling protocol, and implant macrogeometry. In lowdensity bone, osseodensification has emerged as an alternative technique to
optimize initial mechanical stability by promoting lateral bone condensation and
apical compaction. This experimental study aimed to evaluate the influence of
implant macrogeometry (Epikut – E versus Strong SW – SW, SIN Implant
System), associated with the osseodensification technique, on primary stability
and peri-implant bone microarchitecture. Forty implants were placed in ten
porcine tibiae under ex vivo conditions using the epiphyseal region. Osteotomies
were prepared using Densah® burs according to the osseodensification protocol.
Subsequently, twenty implants of each macrogeometry were inserted in a
standardized and balanced distribution between the superior and inferior portions
of the tibial plateau. Primary stability was assessed by insertion torque and
resonance frequency analysis (implant stability quotient, ISQ) by a single
calibrated operator. Bone cores containing the implants were then harvested
using a trephine bur and stored in 70% ethanol for micro-computed tomography
(micro-CT) analysis (13-µm isotropic voxel size). Additional core bone samples
collected away from the implant sites were used as the control group. After the
microarchitectural analysis, three specimens from each group were randomly
selected, embedded in methyl methacrylate, previously labeled with Xylenol
Orange, and evaluated by fluorescence microscopy. The results demonstrated
no statistically significant differences between implant macrogeometries
regarding insertion torque or ISQ values. Micro-CT analysis revealed that, when
associated with osseodensification, the Epikut group exhibited greater trabecular
thickness, whereas the Strong SW group showed a lower trabecular number and
greater trabecular separation compared with the control group. No significant
differences were observed between the two implant macrogeometries. Digital
insertion torque showed a positive correlation with bone volume fraction and
trabecular thickness. Qualitative peri-implant tissue analysis demonstrated areas
of increased bone condensation and morphological patterns consistent with
trabecular compaction and reorganization, corroborating the quantitative findings
obtained by micro-CT. Regions corresponding to the epiphyseal endochondral
ossification zone were also identified, leading to the exclusion of these specimens
from the statistical analysis because the cartilage areas would interfere with the
peri-implant volume of interest used for microarchitectural evaluation. It was
concluded that implant macrogeometry, when associated with the
osseodensification technique, did not significantly influence primary stability
under the experimental conditions evaluated. Conversely, osseodensification
promoted changes in the peri-implant bone microarchitecture consistent with
trabecular compaction and reorganization, providing a biomechanically more
favorable environment for initial implant stability. These findings suggest that the
modifications induced by the osteotomy preparation technique exert an influence
on the initial biomechanical behavior than the differences in implant
macrogeometry evaluated in this study.