A influência das ações de vento e sísmicas no dimensionamento de edifícios de alvenaria estrutural de múltiplos pavimentos
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
Although seismic actions are not yet routinely considered in the design of structural masonry buildings in
Brazil, the publication of ABNT NBR 15421:2023 introduced criteria for accounting for these actions in
such structures. In this context, this study aimed to investigate the influence of building height on the design
of structural masonry buildings subjected to wind, out-of-plumb, and seismic actions. To this end, two
buildings with the same architectural configuration, comprising four and twelve stories, were analyzed for
Site Class D and all Brazilian seismic zones, using seismic response modification coefficients R = 1.5 and
R = 3.0. The design criteria of the current standard were also compared with those of the Draft Revision
of ABNT NBR 16868-1. The analyses included the distribution of horizontal actions; structural
verifications for shear, compression, and flexural tension; and an assessment of the reinforcement required
in the critical wall, as well as the number of walls failing the seismic design checks relative to those
governed by wind and out-of-plumb actions. The results indicated that, for the buildings analyzed, seismic
actions had a greater influence than wind and out-of-plumb actions, with this difference being more
pronounced in the twelve-story building. Furthermore, the Draft Revision generally resulted in a more
conservative design for shear and flexural tension checks, increasing the number of walls requiring
reinforcement. It is concluded that considering seismic actions through the Equivalent Lateral Force (ELF)
method can significantly affect the design of structural masonry buildings, even in regions of low
seismicity, and that, for the structural configuration investigated, the twelve-story building exhibited
greater sensitivity to seismic effects than the four-story building.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto