Estudo comparativo da tratabilidade de efluente de laticinio através de processo oxidativo avançado
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora
DOI
Abstract
Due the fact of the wastewaters’ high pollutant potential produced by dairy
industries and the need of maintenance of water resources, the present
dissertation for the grade of Master in Applied Ecology to Management and
Conservation of Natural Resources have a main proposal to show
alternatives of minimization of organic matter, with the use of Advanced
Oxidative Process (AOP) through of the Fenton’s Reactant. Two reaction
environments was tested, with total an partial light incidence and two types
of add reactants, in two steps and in continuous mode, in sense of reach the
best arrangement to the BOD5,20 and COD removals. To knowledgement of
the dynamic of removal of BOD5,20 and COD, the concentration of this
parameters was followed at each 30min, during 2h. Wastewaters of two
different dairy industries in Zona da Mata was used in the experiments. The
results guide to the best reaction arrange, that was done in continuous mode
with total light incidence, where meaningful BOD5,20 and COD removals
happens in the first hour of treatment, making the treated wastewater more
susceptible for biological treatment in subsequent levels.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Rights and licensing
Acesso Aberto