Acurácia da tomografia computadorizada de feixe cônico no diagnóstico da adaptação marginal de dentes reconstruídos com o sistema cerâmico à base de dissilicato de lítio
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
Abstract
This study investigated the accuracy of cone-beam computed tomography (CBCT)
compared to digital interproximal radiography in evaluating the marginal adaptation of
teeth reconstructed with full lithium disilicate crowns. The influence of artifacts on the
identification of gaps was also assessed by quantifying the contrast-to-noise ratio
(CNR) in CBCT examinations obtained from two equipment. Thirty molars restored
with lithium disilicate full crowns with adapted proximal surfaces and gaps of 0.3 and
0.5 mm were subjected to CBCT and radiographic examination. Six examiners, three
prosthodontists and three radiologists, evaluated the proximal surfaces of the teeth for
the presence or absence of gaps. One ROI (region of interest) was selected in an axial
slice for CNR quantification. To evaluate the detection of marginal gaps in different
image types, the area under the ROC curve, accuracy, sensitivity and specificity were
calculated, considering the gap size, for each examiner and imaging examination. The
Mann-Whitney U test was used to compare the diagnostic test results considering the
independent variables "gap size" and "examiner group," and the Kruskal-Wallis test
was used for the variable "imaging examination". Contrast-to-noise ratio values were
compared between the two CT scanners using the Mann-Whitney U test. The results
showed significant differences in the area under the ROC curve, accuracy, and
sensitivity for gap detection, as well as between imaging exams in relation to diagnostic
tests and between the CNRs from different equipment. No significant differences were
observed between radiologists and prosthodontists. It can be concluded that CBCT
showed accuracy in evaluating the marginal adaptation of lithium disilicate crowns,
performing better than intraoral digital radiography. The significant difference observed
in relation to CNRs reflected the different acquisition protocols used. Regarding the
detection of different gap sizes, significant differences were observed between the
AUC ROC values, accuracy, and sensitivity. No significant differences were observed
in the diagnosis when performed by prosthodontists or radiologists.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Embargado