This paper presents the design and experimental validation of a multivariable
robust control strategy applied to a prototype of the Brazilian Synchrotron Light
Laboratory booster current source. The source, tasked with delivering a triangular
waveform current, necessitates precise tracking with an error tolerance of less than 100
parts per million, in order to precisely inject electrons into the storage ring. Characterized
by a complex, high-order multi-input multi-output structure with multiple series and
parallel power modules, the system complexity is addressed through a model reduction
technique based on the Hankel norm. Leveraging the reduced-order plant during
controller design not only simplifies the system but also results in a lower-order controller.
To guarantee robust stability and performance for the full-order plant, the approximation
error is reintroduced as uncertainty into the reduced-order model. The controller design
employs a weighted H∞ approach. Experimental validation using a small-scale prototype
confirms the effectiveness of the proposed methodology in achieving precise tracking and
robust performance. Finally, the results enable the analysis of the control effort, the
current error in ppm, the current-sharing balance between the parallel connection, and
the comparison with classical control techniques.