Otimização das análises de leite para detecção de soro por espectroscopia de infravermelho
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
The dairy production chain is of great economic and social importance to Brazil, with
the country being the third largest producer of milk in the world. The addition of whey
to the milk is one of the most common frauds, jeopardizing the quality and nutritional
value of the food. Fraud detection has been carried out using traditional analytical
methods, but electronic equipment, such as infrared spectroscopy, is also being used
to facilitate the evaluation of milk quality. The aim of this study was to develop a
predictive and/or classifying model to detect the addition of whey in quantities that
would allow the milk to be classified according to Normative Instruction N°68.
Evaluating the efficiency of the near-infrared spectroscopy method in the
quantification/detection of whey in raw milk and comparing it with the method used in
routine use, the c-Gmp Kit. In the study, samples of raw milk were collected during the
milk reception routine at the Nestlé factory in Montes Claros, Minas Gerais. The
samples were divided into two groups: blank samples, which had no adulteration with
serum, and adulterated samples, which had intentional addition of serum. A total of
886 samples of the routes received at the unit between January 2022 and August 2023
were collected. To check for intentional contamination during the study, analyzes of
the CMP index of 5 levels of the concentrations used (0 - free of addition, 30 mg/L, 50
mg/L, 50 mg/L, 70 mg/L, 100 mg/L and 150 mg/L) were performed. The checks were
performed by the HPLC method as well as by the c-GMP kit. The method showed a
good correlation with the HPLC methodology. However, when comparing the method
with the c-GMP kit, it was observed that the equipment was not able to quantify
satisfactorily at levels between 30 mg/L and 75 mg/L. However, the equipment
demonstrated that when taking readings at levels above 75 mg/L, it also quantifies at
lower levels (between 30 mg/L and 75 mg/L), which may be useful in quantifying levels
above 75 mg/L. To reduce the error found in the detection method, it will be necessary
to carry out a more in-depth study and to develop the use of other tools, such as
Artificial Neural Networks (RNA).
Description
Keywords
Citation
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto

