Desenvolvimento de dispositivos de baixo custo impressos em 3D para o monitoramento voltamétrico do herbicida diuron em amostras de bebidas e água
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
Abstract
This work presents the development of low-cost electrochemical sensors produced by
3D printing using recycled materials, applied to the determination of the herbicide diuron (DIU)
in different matrices. The electrodes were constructed using a conductive composite material
containing graphite and recycled polymer, acrylonitrile butadiene styrene (ABS), in accordance
with the principles of sustainability, green chemistry, and circular economy. The optimization
of the electrode composition allowed the fabrication of devices with high sensitivity and
selectivity. Additionally, a modification was performed by incorporating metal-organic
frameworks (MOFs) and gold nanoparticles, aiming to enhance the electroanalytical response.
The sensors were applied in voltammetric and amperometric methods for the determination of
DIU. The 3D-CPE electrode was employed for the analysis of sugarcane juice and cachaça
samples by square wave voltammetry (SWV), with linear ranges between 0.25–2.5 and 5–20
µmol L⁻¹, and a detection limit (LOD) of 0.07 µmol L⁻¹. It was also used for the analysis of
cachaça samples by flow injection analysis with amperometric detection (FIA-AMP), showing
a linear range between 10–50 µmol L⁻¹ and an LOD of 1.05 µmol L⁻¹. The modified sensor,
3D-CPE/MIL-53(Al)-TDC/AuNP, was applied for the determination of DIU by differential
pulse voltammetry (DPV) in tap water, river water, and lake water samples, showing a linear
range of 0.99–19.2 µmol L⁻¹ and an LOD of 0.04 µmol L⁻¹. The recovery values obtained
ranged from 97 to 107%, confirming the precision of the methods developed. Additionally, a
method was developed capable of simultaneously quantifying DIU and carbendazim (CBZ) by
DPV, with linear ranges of 2–10 µmol L⁻¹ for both. The calculated LOD was 0.52 µmol L⁻¹ for
DIU and 1.07 µmol L⁻¹ for CBZ. This method shows potential for application in environmental
monitoring or quality control analyses. The results demonstrate that the proposed sensors are
efficient, sustainable, and affordable, representing a promising alternative for monitoring
emerging contaminants in different matrices, with potential contribution to sustainable
development goals.
Description
Keywords
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto

