Avaliação do volume remanescente de material obturador em molares retratados com diferentes sistemas: estudo ex vivo em TCFC
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora - Campus Avançado de Governador Valadares
DOI
Abstract
Bacteria and their toxins play an important role in the etiology and progression of pulp
and periapical inflammation; therefore, root canal therapy becomes necessary. After
the failure of primary endodontic treatment, the first option is non-surgical
retreatment. Thus, the aim of this study was to compare the effectiveness of different
retreatment techniques in removing root filling material in maxillary molars using
cone-beam computed tomography (CBCT) images with high resolution. Forty
extracted first maxillary molars were endodontically treated with rotary instruments,
obturated, and subjected to CBCT. For retreatment, ProTaper-R (PR) and WaveOne
Gold (WOG) systems with and without solvent were used for removing the root filling
material. After reinstrumentation, new CBCT images were obtained with and without
the use of the metal artifact reduction (MAR) tool using the same parameters. The
images were qualitatively analyzed by two evaluators for the identification and
location (root third) of the remaining material. For quantitative evaluation, the volume
of remaining material was calculated using ITK-SNAP® software. In R software,
mixed logistic and linear regression models were used to check associations
between variables (p<0.05). More than half of the teeth (66.7%) had only 3 canals,
and of the 130 canals, more than half (64%) had remaining root filling material. The
removal of root filling material using the WaveOne Gold system was more efficient
compared to ProTaper-R. Regarding the solvent, in the ProTaper-R system, the
volume of remaining material without solvent was greater than the volume identified
with solvent. In the WaveOne Gold system, the difference was not significant. The
MAR tool did not influence the assessment of remaining material in the CBCT exam.
It was concluded that the removal of root filling material in maxillary molars was more
efficient with the WaveOne Gold system. The volumetric analysis using ITK-SNAP®
was also noticeably important, as it allowed visualization of the volume of remaining
material according to the system used.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Embargado

