Avaliação dos impactos das variações sistêmicas nas análises de viabilidade do religamento monopolar através do ATP via Python
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
This dissertation presents a new approach to evaluate the impacts of systemic
variations on the success analysis of the monopolar auto reclosing performed in the basic
design stage for transmission lines integrated into the national interconnected system. As
shown in the statistics, approximately 80 % of short circuits in the power system are caused
by phase-to-ground faults. In this context, whenever possible, it is recommended to adopt
the practice of monopolar reclosing instead of tripolar reclosing, due to its systemic benefits
such as reduced torsional stresses on machines, lower transient overvoltage during switching
operations, and reduction in the intensity and duration of voltage sags, among others.
The success of monopolar auto reclosing is closely related to the elimination of secondary
arc currents induced by healthy phases and parallel-operating circuits. Therefore, in the
design stage of new transmission lines, it is essential to seek alternatives that minimize the
secondary arc current, which consequently increases the probability of successful reclosing.
The evaluation of such alternatives is commonly performed using electromagnetic transient
programs such as ATP, PSCAD, EMTP-RV, among others. In this dissertation, the
transient solution of the system will be carried out using ATP. Although this software has
features to compute multiple scenarios, managing and analyzing the impacts of various
system variations on transient responses can become a challenging task prone to errors.
Considering the above, the main objective of this work is to present a methodology that
allows simulations in ATP through master algorithms implemented in Python, which can
operate ATP files to perform specific simulations with predefined parameters. Thus, it
becomes possible to analyze the behavior of secondary arc current and transient overvoltage
induced in the system as a function of parameter variations such as the neutral reactor
value, line length, compensation level, typical line silhouette topology, etc. For the case
studies, typical structures were considered for voltage levels of 230 and 500 kV. For the
latter, both conventional and high surge impedance loading lines were modeled, which
have become increasingly common in planning solutions for carrying large amounts of
generation to load centers. As results, the work graphically presents the behavior of
monitored quantities in the monopolar auto reclosing analysis as a function of the changes
for each studied line. These graphs allow for sensitivity analysis and can assist in the
design and definition of solutions that seek to enable monopolar reclosing.
Description
Citation
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto