Desenvolvimento de argamassa termoisolante para revestimento de paredes de alvenaria em edificações com uso de areia de britagem e vermiculita
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
Throughout their life cycle, buildings consume electrical energy with air
conditioning equipment. The growing global concern about the efficient use of natural
resources and the climate crisis imply the adoption of public policies and construction
strategies that make buildings more efficient in terms of thermal performance. The present
work aims to develop cement rendering mortars with low thermal conductivity walls,
composed of crushed sand from the Juiz de Fora-MG region and expanded vermiculite. A
reference cement and sand mortar was studied in a 1:6 volume ratio and three mortars with
replacement levels of
with and without air-entraining additive (0.035% of the cement mass). In order to
characterize the mortars produced, mechanical resistance tests, water absorption by
capillarity, dynamic modulus of elasticity, density and thermal conductivity were carried
out in experimental equipment, developed at the Federal University of Juiz de Fora, with
results validated by a commercial equipment. Using computer simulation, energy savings
were evaluated wi -
RJ, with a hot climate, and São Joaquim-RS, with a cold climate. The V30A mortar – 30%
vermiculite and additive – showed the greatest reductions in the values of compressive
strength (59%), tensile strength (33%), thermal conductivity (61%) and dynamic modulus
of elasticity (72%), in relation to the reference mortar, without vermiculite and additives.
The annual energy savings obtained with the use of V30A mortar in the building envelope
analyzed in relation to the simulation with conventional mortar was 3.15% for Rio de
Janeiro (bioclimatic zone 8) and 4.90% for São Joaquim ( bioclimatic zone 1). It is
concluded that the use of vermiculite is effective in reducing the thermal conductivity of
the mortars studied, but its use in coatings must be combined with other construction
solutions – roofing, for example – for the most important thermal performance of
buildings.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto