Investigação das propriedades do sinal eletromiográfico do músculo bíceps braquial em diferentes níveis de força isométrica voluntària
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora
DOI
Abstract
Introduction: Central nervous system (CNS) uses the motor unit recruitment and
the rate coding of the recruited units to control the voluntary force exerted by a
muscle. Surface electromyography (sEMG) can be used to capture the electrical
signal resulting from the summation of the action potentials of the muscle fibers
recruited during the force production. The analysis of the variable root mean
square (RMS) and median frequency (Fm) has been used to extract information
about the control mechanisms of force used by the CNS. Objectives: To
investigate the properties of the electromyographic signal through RMS and Fm
variables and analyze the power density distribution in frequency bands in
isometric force levels equal to 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80% and
90% of maximal voluntary isometric contraction (MIVC). Methods: The signals
were obtained bilaterally from the isometric contraction of the biceps brachii
muscle of twenty young healthy volunteers in submaximals force levels. An
algorithm was developed to identify the ideal section of the electromyographic
signal to be analyzed. The variable RMS, Fm and power density distribution in
frequency bands of 5 Hz and 10 Hz were calculated. Results and discussion:
The variable RMS increased linearly with increasing force, as expected. The
variable Fm had increased between 10% and 30% MVIC and than decreased
toward high force levels. This behavior can be related to the experimental protocol
as described in the literature. The analysis of the power density distribution in
frequency bands showed a concentration of power density in the range between
40 Hz and 50 Hz in 10% MIVC. This power density concentration progressively
reduced in 20% to 30% of the MIVC and occurs again on the same frequency
range in 40% MVIC. This behavior may be related to increased fibers type IIa and
IIb to the force production process. From 40% to 90% of the MIVC the
concentration in power density in range between 40 Hz and 50 Hz decreases.
Conclusions: The variables extracted from the EMG signal showed behavior
compatible with the protocols described in the literature containing submaximal
contractions at different levels of MIVC. Their variations may be related to
differences in experimental protocol. The analysis of power density distribution in
frequency bands can provide additional information being related to the
recruitment and rate coding of motor units during the increase in voluntary force.
Description
Keywords
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Rights and licensing
Acesso Aberto