Avaliação de diferentes tratamentos de superfície na resistência à flexão biaxial e nas características microestruturais e topográficas de uma cerâmica feldspática reforçada por leucita
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
This study aimed to evaluate the influence of surface treatment on biaxial flexural
strength, roughness, microstructure and composition of glass ceramics. Fifty-four
ceramic disks (diameter: 12 mm; thickness: 1.2 mm) were obtained from leucitereinforced feldspathic CAD/CAM blocks (IPS Empress Cad Cerec, Ivoclar Vivadent).
The discs were divided into three groups (n=18), according to the surface treatment:
hydrofluoric acid 5% 20 s and silane (HF20); 5% hydrofluoric acid 60 sec and silane
(HF60); and self-etching ceramic primer (P). For roughness analysis in a digital optical
profile meter, microscopy and chemical analysis (energy dispersive X-rays – EDS) in
a scanning electron microscope, analysis of the contact angle in a goniometer and
knoop hardness in a microdurometer, three samples from each group were used. The
remaining 15 were cemented on an epoxy resin disc (diameter: 12 mm; thickness: 2.3
mm), material analogous to dentin with dual resin cement, and drinks to mechanical
fatigue (1.2 x 106 cycles, 50N, 3, 8 Hz) and the biaxial flexion test (1 mm/min; 1,000
Kgf). Biaxial flexural strength (MPa) and roughness (μm) data were submitted to oneway analysis of variance (ANOVA) and Tukey's test (5%). For HF20, the result was
statistically superior to HF60 (p < 0.001); P was similar to the others. Weibull indicated
that the most reliable treatment was P. Regarding the accommodation time, it was
tolerated that the time of 60 s significantly increased the average value of surface
roughness (p < 0.001), compared to 20 s. Surface micrographs indicated a greater
change in the HF groups compared to the P groups. In the EDS, it was noted that the
percentage of silica was high. Transient microscopies in the HF groups showed an
increase in the innocence of the vitreous matrix and exposure of the other contents.
As for the P group, a greater surface homogeneity is observed. In the evaluation of
knoop hardness (HK), the highest value obtained was for the P group. For the analysis
of the contact angle (º) the lowest degree found was for the HF60 group. It is concluded
that the type of surface treatment interferes with the roughness and resistance of the
ceramic treated with leucite when different settling times with HF are used. Thus, the
self-etching ceramic primer can be a satisfactory alternative for etching the studied
glass ceramic, as it promoted topographic changes without the need for HF acid.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto