Uma nova metodologia para estimação de estados em sistemas de distribuição radiais utilizando PMUs

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Universidade Federal de Juiz de Fora

DOI

Abstract

This work aims at presenting a new methodology for static state estimation in electric power distribution systems which estimates the branch currents as state variables using voltage measurements and current phasor branch obtained from phasor measurement units (Phasor Measurement Units - PMUs). The methodology consists of solving a nonlinear optimization problem minimizing a quadratic objective function associated with the estimated measurements and states, subject to load constraints for the non monitored loads based on historical data, which is the main contribution of this work. A PMU allocation strategy is presented which consists of allocating two PMUs for each system branch, one at the beginning and another at the end, trying to use as little PMUs as possible in such a way that the quality of the estimated states are not compromised. The solution of the optimization problem is obtained through two ways, the first is the toolbox ‘fmincon’ from Matlab solver software which is a widely used tool in the optimization problem. The second is a computer implementation of interior point method with security barrier (SFTB - IPM) proposed in the literature. Comparisons of computing times and results obtained with both methods are shown. A power flow program is used to obtain the voltages and branch currents in order to emulate the PMUs data in the state estimation process. Additionaly the non monitored loads are varied from the minimum bounds to their maximum, allowing white noise errors from the PMUs measurements. A tutorial test system of 15 buses is fully explored and three IEEE test systems of 33, 50 and 70 buses are used to show the effectiveness of the proposed methodology. For the tutorial and 70 bus systems, distribued generation units were included to see the state estimator behavior. All results from the state estimation process are obtained considering the two presented solving methods and the computing times performance compared. The results obtained were validated using a conventional power flow program and have good accuracy with low objective function value even in the presence of white noise errors in the measurements reflecting the reliability of the proposed methodology, making it very attractive for distribution system monitoring.

Description

Citation

Endorsement

Review

Supplemented By

Referenced By

Rights and licensing

Acesso Aberto