Detecção de SARS-COV-2 (COVID-19) através da técnica de amplificação isotérmica mediada por LOOP (LAMP)
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
Abstract
In 2019, the COVID 19 pandemic caused by the Sars-Cov2-2 virus resulted in millions
of cases and deaths worldwide. The diagnosis of the new coronavirus during the
COVID-19 pandemic was essential to prevent the spread of the virus and monitor the
dynamics of the infection. The main tests for diagnosing COVID-19 include serological
and molecular tests. Here, we describe a molecular diagnostic method for the detection
of SARS-CoV-2 through the Loop-mediated isothermal amplification (RT-LAMP)
technique. We used this technique to detect and amplify genetic sequences of SARSCoV-2 using a set of primers that target regions that encode the N protein. For
standardization, we analysed RNA from 858 samples from patients already tested for
SARS-CoV -2 by RT-qPCR. The RT-LAMP technique has some obstacles such as
false positive and false negative results that can be caused by the acidic pH in the
reaction. Therefore, in this study, we evaluated the specificity, sensitivity and accuracy
of the RT-LAMP reaction with and without pH adjustment, seeking to standardize the
technique to obtain more reliable results. Here we used a total of 868 samples from
patients with examination, which were strengths in, in the first analysis, groups
according to three syndrome assays performed as the manufacturer, without pH
adjustment, and tested an accuracy of 50.96% (k =0.041) compared to RT-qPCR
results.This accuracy was improved in the group whose RT-LAMP reaction was pHcorrected to 8-9, with an accuracy of 72.22% (k=0.484). We also observed that the
sensitivity increased from 82% (95% CI, 68.56-91.42) to 92.19 (95% CI, 82.70-97.41),
the same happening with the specificity, going from 22.22 (95%CI, 12.04 -35.60) to
56.25 (95%CI, 43.28-68.63), after pH adjustment. After standardization with real-time
RT-LAMP (rtRT-LAMP), the accuracy was 71.57% (k=0.42), the sensitivity was
77.99% (95% CI, 71.76-83.41), and the specificity improved with 68.35% (95% CI,
63.64-72.79). These data demonstrate that pH adjustment is important to obtain better
results in the RT-LAMP technique, contributing to the validation for the development of
diagnostics based on LAMP.
Description
Keywords
Citation
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Embargado