Estudo experimental, numérico e analítico de colunas granulares encamisadas
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
Abstract
Structures on soft soil deposits are a challenge for geotechnical engineering due to their low
bearing capacity and high compressibility. Stability with granular encased columns is one of
the most used solutions, however, when applied to extremely soft soils, there may be no lateral
confinement. For this, a geosynthetic casing is used, which promotes additional confinement,
leading to the mobilization of greater shear strength. Thus, it’s important to deepen the study
on the action of lateral loading, since the request can occur at the tip of the embankments and
in the movement of soil during earthquakes. Thus, the objective of this document is to analyze
the behavior of granular encased columns behavior subjected to shear, approaching the
methodology of Raithel and Renne (2000), performing direct shear tests in miniaturized GEC's,
and numerical modeling representative of the behavior observed in the reduced model. (1g
type). In the field, the use of granular encased columns takes place in soft soil, however, for the
simulation, sandy was used to fill the column and the area surrounding it. The material was
rained with relative densities of 40% and 100%. Direct shear strength tests were carried out
with a granular encased columns with LDPE plastic canvas (stiffness equal to 20, 40, 80 and
160 kN/m) and plastic film (1.34 and 3.46 kN/m), seeking to obtain rigidities equivalent to
those used in practice. A group analysis was also performed with LDPE plastic tarpaulin lining
with 1, 2, 4 and 9 columns. Numerical analyses were carried out using the PLAXIS 3D software
in order to verify the occurrence of liner rotation during shear and the deformation of the
geosynthetic associated with the post-peak condition. The comparison of the tests with the
metodology of Raithel and Henne (2000) was carried out with the results obtained with the
lining in plastic film. The results showed that the addition of columns and the stiffness of the
casing increases the shear strength of the set. The calculation method for increased friction
angle led to satisfactory values. The calculation method for increased cohesion had a small
correspondence with the values obtained in the tests. The numerical modelling has shown that
GEC's do not rotate significantly at the base of the shear box and its fixation is not necessary
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto