Abstract
Corrosion, especially the one that occurs in steel, can cause numerous inconveniences,
damages, and economic losses in a wide variety of activities, due to the deterioration caused by
different materials. Corrosion-related processes in the oil and petrochemical industries cause
major losses throughout the production chain. The use of corrosion inhibitors is one of the most
commonly used methods to control and reduce corrosive processes in these industries. Both
corrosion inhibitors and scale inhibitors may be present in the water produced during oil
extraction, which is a by-product in oil exploration, having a very complex matrix, containing
various organic and inorganic substances, being potentially harmful to the environment, if the
disposed properly. In Brazil, the disposal of produced water is regulated by CONAMA norm
393/2007, which limits the content of oils and greases (TOG) to a maximum monthly average
concentration of 29 mg L-1
, with a daily maximum value of 42 mg L-1
. In this scenario, SERS
spectroscopy has great potential for the analysis of corrosion inhibitors, especially those present
in the production water, since this technique has a high sensitivity to organic analytes, in
addition to providing important vibrational information of the molecules studied. In the present
work, paper (cellulose) was used as a support for AuNP and AgNP immobilized at different
concentrations for the construction of high-performance SERS substrates, which were
investigated for the detection of the commercial corrosion inhibitors benzotriazole,
benzimidazole, and L-methionine. Among the constructed substrates, the immobilization of
AgNP on cellulose showed the best response for the application of the SERS technique to
corrosion inhibitors at low concentrations. Experimentally, it was verified that the power
density of the laser used (λ0= 632.8 nm) must be low, to avoid the degradation of the analytes.
Using a nominal power of 5 mW from a He-Ne laser line at 632.8 nm, spectra of the corrosion
inhibitor with a high S/N ratio were obtained at very low concentrations such as 1.0×10-7 mol
L
- 1
for benzotriazole. These results indicate that it is possible to obtain SERS spectra at very
low concentrations of inhibitors on AgNP/paper substrates. For the corrosion inhibitors
benzimidazole and L-methionine, the obtained spectra had Raman signal enhancement using
AgNP; however, the process of photodegradation and formation of amorphous carbon did not
allow obtaining high signal-to-noise ratio spectra.