Acurácia de medidas lineares em TCFC para planejamento de implantes osteointegráveis em regiões adjacentes à artefatos metálicos
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora - Campus Avançado de Governador Valadares
DOI
Abstract
The objective of this study was to evaluate the influence of the presence of
metallic artifacts in the accuracy of linear measurements for preoperative
planning of dental implants, in images of cone-beam computed tomography
(CBCT) obtained with different acquisition protocols. The study was based on the
evaluation of bone height and thickness, in the anterior and posterior mandible
region, of three dry skulls, which were submitted to CBCT, with nine acquisition
protocols, with and without the presence of metallic artifacts (fused metal
cores).The acquisition protocols used different voxels (0.2, 0.25 and 0.4 mm),
FOVs (field of view) (16 x 13 and 16 x 08 cm) and degree of rotation of the
apparatus (180o and 360 o). Three evaluators, with experience in tomographic
images, evaluated each CBCT exam three times, with a week's interval. To verify
intra- and inter-rater reliability, the intraclass correlation coefficient (ICC) was
calculated. Two-factor ANOVA was used to compare the measurements in the
groups, with Tukey's post-hoc test, with significance level set at 5%. The ICC
values ranged from 0.92 to 0.99 for the intra-, and 0.93 to 0.98 for the inter-rater
tests. In the posterior region, the bone height values were significantly lower in the
presence of metallic artifacts for all acquisition protocols, except for protocol 1
(voxel 0.2 mm, FOV 16 x 13 cm and 360 o) (p = 0.392). In the anterior region, the
observed values for measurements with smaller voxel size, independently of FOV
and rotation degree showed to be more reliable. In the evaluation of the accuracy
of bone thickness measurements in the posterior region, there was no significant
difference between groups with and without metallic artifacts, regardless of the
acquisition protocol used. In the anterior region, in the presence of artifacts, the
protocols with the smallest voxels, showed lower approximation with the actual
values. It can be concluded that the measurements of bone height and thickness
for the planning of dental implants in the mandible may be affected by the
presence of metallic artifacts in adjacent anatomical regions.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto