Please use this identifier to cite or link to this item: https://repositorio.ufjf.br/jspui/handle/ufjf/2636
Files in This Item:
File Description SizeFormat 
jonasalmeidanevesmartins.pdf654.93 kBAdobe PDFThumbnail
View/Open
Type: Dissertação
Title: Variáveis de controle do esforço em bicicleta aquática
Author: Martins, Jonas Almeida Neves
First Advisor: Lima, Jorge Roberto Perrout de
Referee Member: Novo Junior, José Marques
Referee Member: Kruel, Luiz Fernando Martins
Resumo: A bicicleta aquática Hidrocycle® possui sistema para gerar resistência, denominado Evolution®, que consiste em quatro calhas retangulares dispostas perpendicularmente movimentadas pelo giro dos pedais. Neste sistema há duas maneiras para controlar a carga: 1) velocidade de pedalada (RPM) e 2) alteração da área frontal das calhas (AF) em três níveis, AF1, AF2 e AF3. Para utilização mais precisa no treinamento, torna-se necessário o estudo das variáveis que atuam no controle da intensidade do exercício do sistema Evolution®, freqüência cardíaca (FC), percepção do esforço (PE), tensão muscular, consumo de oxigênio (VO2), gasto calórico e concentração de lactato [La] em resposta às variações de RPM e AF. Portanto, os objetivos do estudo foram verificar: 1) A resposta da FC e PE em teste progressivo de esforço realizado em duas profundidades, cicatriz umbilical e processo xifóide; 2) Identificar VO2max, [La]max, FCmax e PE para cada AF do sistema Evolution® em protocolo progressivo de cargas e predizer o gasto calórico e potência gerada protocolo de carga submáxima constante. Para o estudo 1, a amostra foi constituída por 10 homens e mulheres ativos, submetidos a dois testes progressivos, um em cada profundidade. Para o estudo 2, 15 homens, fisicamente ativos realizaram 3 testes máximos, um com cada AF e um teste de carga constante submáxima para predição do gasto calórico e potência gerada. No estudo 1, os valores máximos de FC e PE apresentaram diferenças estatisticamente significantes ao serem comparados nas duas profundidades. Já a FC por estágio de RPM, apresentou a partir do terceiro estágio tendência a ser mais alta, sendo evidente a diferença a partir do sétimo estágio na altura do processo xifóide. O estudo 2 verificou-se que não há diferença nos valores máximos de FC, VO2, [La] e PE nas 3 AF estudadas em teste máximo, porém os valores ocorrem em RPM diferentes, revelando que quanto maior a AF, menor é a RPM para se atingir os máximos para FC, VO2, [La1] e PE. Para o mesmo estudo, permitiu predizer o VO2 a partir das variáveis AF, RPM. Conclui-se que o sistema Evolution® da bicicleta aquática Hidrocycle® permite adequar a sobrecarga de exercício, assim como sua predição facilitando a aplicação do equipamento nas diversas áreas do treinamento físico.
Abstract: The aquatic bicycle Hidrocycle® has a system to generate resistance, called Evolution®, which consists of four rectangular troughs arranged perpendicularly moved by the rotation of the pedals. In this system there are two ways to control the load: 1) the pedaling speed (rpm) and 2) change in the frontal area of ducting (AF) in three levels, AF1, AF2 and AF3. To use more precise training, it is necessary to study the variables that act in the control of exercise intensity Evolution® system, heart rate (HR), perceived exertion (PE), muscle tension, oxygen consumption (VO2) and lactate concentration [La] in response to changes in RPM and AF. Therefore, the objectives of the study were: 1) The response of HR and PE in the progressive effort test performed at two depths, umbilicus and xiphoid process, 2) Identify VO2max, [La]max, and PE for each AF system Evolution ® protocol in progressive loads and to predict the VO2. For study 1, the sample consisted of 10 active men and women who underwent two progressive tests, one in depth. For study 2, 15 men, physically active performed area submitted to 3 maximal tests, one each with AF and a test of submaximal constant workload to predict the caloric expenditure and power generated. In study 1, the maximum values of HR and PE showed no statistically significant differences when comparing the two depths. The HR for stage RPM, presented from the third stage tend to be higher in height of the xiphoid process. In study 2, there was no difference in the maximum values of HR, VO2, [La] and PE in 3 AF studied in maximal test, but the values occur at different rpm, showing that the higher the AF, the less RPM to achieve the maximum for HR, VO2, [La1] and PE. Since the study incremental load predicted VO2 from the variables AF, RPM. We conclude that the system Evolution ® aquatic bicycle Hidrocycle ® to tailor the exercise overload, as well as the prediction equity to facilitate the implementation of the equipment in the various areas of physical training.
Keywords: Freqüência cardíaca
Consumo de oxigênio
Lactato
Percepção do esforço
Heart rate
Oxygen consumption
Lactate
Perception of effort
CNPq: CNPQ::CIENCIAS DA SAUDE::EDUCACAO FISICA
Language: por
Country: Brasil
Publisher: Universidade Federal de Juiz de Fora (UFJF)
Institution Initials: UFJF
Department: Faculdade de Educação Física
Program: Programa de Pós-graduação em Educação Física
Access Type: Acesso Aberto
URI: https://repositorio.ufjf.br/jspui/handle/ufjf/2636
Issue Date: 20-Apr-2010
Appears in Collections:Mestrado em Educação Física (Dissertações)



Items in DSpace are protected by Creative Commons licenses, with all rights reserved, unless otherwise indicated.