Influência de instrumentos endodônticos com diferentes conicidades na qualidade da instrumentação e na remoção de dentina radicular em incisivos inferiores
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora - Campus Avançado de Governador Valadares
DOI
Abstract
The use of instruments with reduced tapers has been suggested for endodontic
treatment to reduce root dentin removal. Thus, the study aims to evaluate the
influence of endodontic instruments with different conicities (.04 and .06) on the
quality of the instrumentation and the volume of dentin removed after the
preparation of lower incisors with circular and oval canals, using microcomputed
tomography ( micro-CT). Forty lower incisors with single canals were subjected
to micro-CT and divided into two groups (n=20): oval canals and circular canals.
The teeth were accessed and prepared with the VDW ROTATE instruments in
the sequence: 15/.04, 25/.06 and 35/.04. After preparation with the 35/.04
instrument, the teeth were re-scanned by micro-CT and prepared with the 35/.06
instrument and the teeth were scanned again. After the scans, the percentage of
unprepared area and volume of dentin removed were calculated in the CTAn
program. The data were subjected to statistical analysis using the Mann Whitney,
Wilcoxon or Student's T tests according to the normality of the samples (P<0.05).
It was observed that in both groups, the percentage of unprepared area was
higher after preparation with conicity .04 when compared to .06 (P<0.05). On the
other hand, the percentage of dentin removed was lower after preparation with
the .04 conicity when compared to .06 (P<0.05). When comparing the type of
anatomy (oval and circular canals) no statistical difference was observed
between the percentage of unprepared area and dentin removed (P>0.05),
however, it was found that the surface area and volume of the canals oval canals
was significantly larger than circular canals, which is justified by the anatomical
difference itself (P<0.05). Therefore, it was concluded that the use of instruments
with reduced conicity (.04), despite removing a smaller amount of root dentin,
promotes a greater percentage of unprepared area of the canal, which can
influence the cleaning of the canals.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto