Correlação entre o diâmetro de incisivos inferiores e dimensões de diferentes instrumentos mecanizados, por meio da microtomografia computadorizada
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora - Campus Avançado de Governador Valadares
DOI
Abstract
Chemo-mechanical preparation is one of the most important phases of
endodontic treatment, but it presents a challenge because no technique or instrument
is capable of promoting complete disinfection of the root canal system. Furthermore,
choosing instruments with taper or tip diameter that are not compatible with root canals
can increase the presence of areas unprepared by instruments, which can harbor
bacteria and tissue debris, leading to unsuccessful of endodontic treatment. Therefore,
the objective of the study was to evaluate the diameters of the root canals of
mandibular incisors and correlate them with the tip diameter and taper of rotary or
reciprocating endodontic instruments to define the ideal dimensions of the instruments
which allow better root canal preparation. Thus, 73 mandibular incisors with no
previous endodontic treatment and no fracture, crack or root resorption were scanned
by microcomputed tomography. Initially, the slice that corresponding the apical
foramen and slice corresponding to the cementoenamel junction (CEJ) were defined.
Then, the largest and smallest diameters of the canals were measured at 0, 1, 2 and
3mm below the apical foramen and the cementoenamel junction towards the apical
foramen. All measurements were automatically determined by the CTAn program after
selecting the root canal region of interest. It was found that the smallest diameter in
the apical 3mm ranged from 0.24 to 0.27mm, while the largest diameter ranged from
0.32 to 0.61mm. In the JCE region, the smallest diameter varied from 0.45 to 0.52mm
and the largest diameter was from 1.16 to 1.23. According to the measurements
obtained, the ideal sizes of instruments to be used on root canal preparation of apical
region are 45/.05 and 50/.04. The ideal instruments to be used in the cervical third are:
25/.07, 25/.08, 40/.06. It was concluded that the original diameter of the mandibular
incisors in the apical region is generally larger than the instruments recommended for
their preparation. However, one must be careful not to use instruments that are too
wide to avoid causing excessive dentin removal and possible accidents during root
canal treatment.
Description
Keywords
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto

