Correlação entre o diâmetro de incisivos inferiores e dimensões de diferentes instrumentos mecanizados, por meio da microtomografia computadorizada

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Universidade Federal de Juiz de Fora - Campus Avançado de Governador Valadares

DOI

Abstract

Chemo-mechanical preparation is one of the most important phases of endodontic treatment, but it presents a challenge because no technique or instrument is capable of promoting complete disinfection of the root canal system. Furthermore, choosing instruments with taper or tip diameter that are not compatible with root canals can increase the presence of areas unprepared by instruments, which can harbor bacteria and tissue debris, leading to unsuccessful of endodontic treatment. Therefore, the objective of the study was to evaluate the diameters of the root canals of mandibular incisors and correlate them with the tip diameter and taper of rotary or reciprocating endodontic instruments to define the ideal dimensions of the instruments which allow better root canal preparation. Thus, 73 mandibular incisors with no previous endodontic treatment and no fracture, crack or root resorption were scanned by microcomputed tomography. Initially, the slice that corresponding the apical foramen and slice corresponding to the cementoenamel junction (CEJ) were defined. Then, the largest and smallest diameters of the canals were measured at 0, 1, 2 and 3mm below the apical foramen and the cementoenamel junction towards the apical foramen. All measurements were automatically determined by the CTAn program after selecting the root canal region of interest. It was found that the smallest diameter in the apical 3mm ranged from 0.24 to 0.27mm, while the largest diameter ranged from 0.32 to 0.61mm. In the JCE region, the smallest diameter varied from 0.45 to 0.52mm and the largest diameter was from 1.16 to 1.23. According to the measurements obtained, the ideal sizes of instruments to be used on root canal preparation of apical region are 45/.05 and 50/.04. The ideal instruments to be used in the cervical third are: 25/.07, 25/.08, 40/.06. It was concluded that the original diameter of the mandibular incisors in the apical region is generally larger than the instruments recommended for their preparation. However, one must be careful not to use instruments that are too wide to avoid causing excessive dentin removal and possible accidents during root canal treatment.

Description

Citation

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwise noted, this item's license is described as Acesso Aberto