Abstract

The use of instruments with a reduced conicity has been suggested based on the assumption of less dentin removal during endodontic treatment. However, it is necessary to verify the actual dentin thickness of the canals after preparation with instruments of different conicities. Thus, the present study aims to evaluate the influence of endodontic instruments with different tapers on the thickness of remaining root dentin after preparation of lower incisors using computed microtomography (micro-CT). A total of 82 teeth were selected and scanned by micro-CT. Subsequently, after applying the inclusion criteria, 40 lower incisors were selected and divided into two groups based on anatomy (n = 20): teeth with circular canals and teeth with oval canals. All teeth were accessed and prepared sequentially using instruments 15/.04, 20/.05, 25/.06, 30/.04, and 35/.04. Afterwards, the teeth were scanned again using micro-CT. After the second scan, the teeth were prepared with the 35/.06 instrument and scanned again to quantify the thickness of remaining dentin after using instruments with tapers of .04 and .06, respectively, using the CTAnalyzer. The normality of the data was assessed using the Shapiro-Wilk test. Student’s T test or the Mann-Whitney test was used for intergroup comparisons. The Intragroup analyses were performed using repeated-measures ANOVA with Tukey’s post-hoc test or the Friedman and Dunn tests (p < 0.05). Initially, the groups had similar dentin thickness (p > 0.05). Root canal preparation significantly reduced dentin thickness in both groups (circular and oval canals) at all levels assessed (p < 0.05). There was no statistically significant difference in linear measurements or in the percentage of reduction between oval and circular canals, regardless of the instrument used (p > 0.05). However, the intragroup analysis revealed that instruments with a taper of .06 caused greater dentin reduction than those with a taper of .04 at the evaluated levels, and in the mesial and distal directions. It was concluded that canal anatomy (circular vs. oval) did not influence dentin wear, nevertheless, however a taper of .06 resulted in greater reduction in dentin thickness compared to a taper of .04.

Description

Citation

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwise noted, this item's license is described as Acesso Embargado