Identificação e localização de falhas em circuitos de via de ferrovias baseada em reflectometria no domínio da frequência
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
This work presents two new methods for the prevention and identification of
failures caused by short-circuit between rails or breakage of them in Railway Track
Circuits (in portuguese is Circuito de Via - CDV). One of the methods (Railway
Track Circuit Fault Locator, LFCDV - in portuguese is Localizador de Falhas em
Circuito de Via) aims to identify and locate faults in track circuits caused by low
impedance points between rails, or broken rails, and is based on the frequency
domain reflectometry technique. The second method (Preventive Measurement in
Railway Track Circuit, MPCDV - in portuguese is Medição Preventiva em Circuito
de Via) was developed to measure the impedance between rails along a rail network
in order to identify low impedance points preventively. Two instrumentation systems
were developed specifically to validate the proposed methods through field tests in
the MRS logistics network. The tests showed that the LFCDV method is able to
identify problems in the CDV and to locate them with good accuracy. Regarding
the MPCDV method, the tests showed its ability to identify low impedance points
for values up to 9.3 , that is, a value much higher than the 0.1 used as an upper
limit to detect when a railway section is not available for traffic, demonstrating the
validity of the proposed method and its implementation.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Rights and licensing
Acesso Aberto