Análise comparativa do comportamento biomecânico de incisivos centrais superiores restaurados com núcleo metálico fundido e pino de fibra de vidro submetidos a movimentações ortodônticas: um estudo de elementos finitos
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
Abstract
This study aimed to analyze, using the finite element method, the
biomechanical behavior of maxillary central incisors restored with glass fiber post
(GFP) and cast metal post and core (CMP) submitted to buccolingual and mesiodistal
orthodontic forces. Two maxillary central incisors were modeled, containing
periodontal ligament, cortical bone and trabecular bone. In one of the models, an
intraradicular restorage of GFP was included, and in the other model, one of CMP.
After the creation of the tridimensional mesh of finite elements, the application of two
orthodontic forces was simulated, one buccolingual of 65 g and another mesiodistal of
70 g. The forces were applied parallel to the palatal plan, in the slot of the bracket
located 4 mm to the incisal edge. The maximum stresses generated in the GFP
restored root were 3,642 x 10-1 MPa and 4,755 x 10-1MPa from the buccolingual and
mesiodistal forces, respectively. Likewise, in the CMP restored root the stresses were
2,777 x 10-1 MPa and 3,826 x 10-1 MPa. The radicular area with higher stress on both
models was located in the cervical third, considering the buccolingual force, that stress
occurred on the buccal surface, and when the mesiodistal force was applied, it occured
on the mesial surface. The CMP structure presented the highest levels of stress. The
radicular stresses that come from buccolingual and mesiodistal orthodontic forces
were lower on the CMP restored incisor. The post materials stresses were lower on
the GFP structure.