Otimização da conexão de geração eólica em sistemas de potência considerando a técnica de Transmission Switching
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
Abstract
The continuous growth of investment in wind energy in recent years has made
Brazil stand out in the world ranking that measures the installed capacity of this type of
generation. Recent studies are focusing on Offshore Wind Farms (OWFs). Considering
the installation of new OWFs in locations pre-defined by wind studies, determining the
best connection points for OWF to the onshore system grid requires a comprehensive
analysis that takes into account technical, economic and environmental restrictions. In
this work, three methodologies are proposed whose objective is to maximize the use of firm
wind energy by determining the ideal connection point for wind farms (WFs), offshore
or not, in an Electrical Power System (EPS), taking into account the electrical losses of
the existing transmission system, as well as the limits of transmission lines and multiple
load scenarios. The first methodology is based on the Optimal Transmission Switching
(OTS) technique and aims to optimally connect an OWF to an onshore system, a topic
that has not been explored much in the literature. This methodology considers a list
of candidate transmission lines for connecting the wind generation. The N-1 security
criterion is also accounted for. The second methodology considers a new formulation of
the Power Transfer Distribution Factors (PTDF). Usually, PTDFs are calculated based on
the fact that the system’s reference bus will absorb any power imbalance. However, one of
the contributions of this work is the proposal of a new PTDF formulation to carry out
a more realistic analysis of a system’s operation, developed based on the Linear Power
Flow (LPF) methodology and the conventional generators’ participation factors. Different
WFs can be connected to the system simultaneously. The results are compared to those
obtained by the original PTDF formulation to determine the benefits of the new approach.
The third methodology is a combination of the other two to take advantage of both. An
OWF is connected via a single connection from a group of candidate lines. Analyses are
carried out considering the daily variations in demand through load levels and the N-1
security criterion. The proposed methodologies were implemented using Python 3 and were
evaluated considering the 6-Bus, 11-Bus, IEEE Reliability Test and IEEE 118-Bus systems.
The results presented validate and demonstrate the effectiveness of the proposed techniques.
Description
Keywords
Fator de distribuição de transferência de potência , Fluxo de potência linear , Fluxo de potência ótimo linear , Geração eólica offshore , Máxima penetração de energia eólica , Optimal transmission switching , Perdas elétricas , Electrical Losses. , Linear optimal power flow , Linear power flow , Maximum penetration of wind energy , Optimal transmission switching , Power transfer distribution factors
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto