Monitoramento da carga de treinamento em atletas de CrossFit® durante um ciclo de quatro semanas
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
CrossFit® is characterized by being a training program that improves physical
performance through different stimuli through functional and constantly varied movements.
Controlling training load has been a constant discussion in science. The literature still lacks
studies that describe the monitoring and control of training load in CrossFit®. Objective:
Monitor training load in CrossFit® athletes over a four-week cycle. Methods: 20 to 24 training
sessions were monitored in nine CrossFit® athletes. Monitoring was carried out every week
through measurements of heart rate (HR), perceived session exertion (RPE-s), monotony,
strain, acute:chronic load ratio (CTAC) and vertical jump (SV). Athletes were observed during
a specific four-week training cycle. Results: HR, RPE-s, total training time (TT), training load
(CT), CTAC, monotony and strain showed normal distribution (p > 0.05). The coefficient of
variation presented relatively ideal values (< 25%), except for the highest “monotony” and
“strain” variables (> 25%). HRpeak, HRmax, RPE-s, TT, CT, CTAC, monotony and strain did
not show the assumed sphericity, but only for HRpeak at different times (p = 0.003). One-way
ANOVA with repeated measures showed that there was no effect for any of the variables
[HRpeak: FGn (1.486, 11.886) = 4.067; p=0.055; PSE-s: F(3, 24)=1.783; p=0.177; TT: F(3,
24)=0.984; p=0.417; CT: F(3, 24)=1.566; p=0.223; CTAC: F(3, 24) = 1.491; p=0.242;
monotony: F(3, 24) =0.258; p=0.855; and strain: F(3, 24)=0.238; p=0.869]. Resting HR and
SV assumed sphericity for the different times (HRrep: p=0.806; SV: p=0.110), but with no effect
of resting HR [F(4, 32) = 1.895; p=0.135] and SV [F(1.955, 15.643) = 3.347; p=0.063].
Pearson's correlation showed that there was no relationship (p>0.05), at any time during
training, between SV and the variables TT, CT, CTAC, monotony and strain. Conclusion: It is
concluded that the values of HRpeak, HRmax and HR at rest did not undergo significant
changes during the four weeks of training monitoring. Regarding RPE-s, monotony and strain
did not undergo significant changes over the four weeks of training. CTAC remained within the
safe training zone and did not undergo significant changes during the four-week cycle.