Avaliação da qualidade do tratamento endodôntico realizado com diferentes tipos de instrumentação
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora - Campus Avançado de Governador Valadares
DOI
Abstract
The root canal system instrumentation is one of the most important stages of
endodontic treatment, contributing to the reduction of microorganisms. Its correct
execution is directly related to a satisfactory obturation, usually evaluated by imaging
exams. Depending on the type of instrumentation used, the results obtained may
vary, especially when evaluating the performance of dental students. The objective
of the present study was to evaluate, through digital periapical radiographs, the
quality of obturation in multiradicular teeth instrumented with different techniques by
dental students. Eighty multiradicular human teeth were selected, which were
cleaned and had their crowns removed. These were instrumented by four dentistry
students. Of the 20 teeth instrumented by each student, 10 were instrumented with
stainless steel hand files and 10 with nickel-titanium (Ni-Ti) rotary files. All teeth were
filled by lateral condensation technique and subjected to periapical radiography
examinations by the semi-direct digital acquisition system with photostimulable
phosphor plates (PSP). The images were evaluated by experienced, previously
instructed examiners, grading the quality of the obturation and whether
complications occurred. To verify intra- and inter-rater agreement, the Kappa test
was performed. To compare the quality of obturation between the different
instrumentation techniques, the McNemar test was used (p <0.05). The evaluation
of the instrumentation quality in relation to the length of the obturator material did not
present significant difference for the two forms of instrumentation. Regarding the
homogeneity of the obturator material, there was no significant difference either.
Comparing the two techniques for the presence or absence of complications and the
frequency of complications, the results were similar. (p> 0.05). It was concluded that
the instrumentation performed by undergraduate apprentices was similar, regardless
of whether hand-operated stainless steel or Ni-Ti rotary files are used, allowing the
operator the freedom to choose the one that is most advantageous to the procedure
to be performed without loss of quality.
Description
Keywords
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto