An online state-of-charge balancing strategy for energy storage STATCOM based on modular multilevel converters
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
Abstract
The increasing integration of renewable energy sources into power systems has
introduced significant challenges related to intermittency and grid stability. In this context,
the Energy Storage Static Synchronous Compensator (ES-STATCOM), based on the
Modular Multilevel Converter topology, emerges as an effective solution to enhance the
flexibility and reliability of power systems. However, the configuration in which battery
racks are connected in these systems, combined with varying operating conditions, can
cause State of Charge (SoC) imbalances among battery modules, reducing both the
system’s efficiency and its lifetime if operated under such conditions. To address this
issue, this dissertation proposes an online SoC balancing strategy employing an algorithm
integrated into the ES-STATCOM control structure. In addition, control loops for output
current regulation and circulating current suppression were designed in the synchronous
dq reference frame. The developed approach enables the SoC balancing process while
simultaneously maintaining the converter’s capability to inject and absorb active and
reactive instantaneous power. This strategy not only improves the utilization of the
Battery Energy Storage System (BESS) but also enhances the operational reliability
of the ES-STATCOM under different grid conditions. The proposed methodology was
verified through detailed simulations using the PSCAD/EMTDC software, where an
ES-STATCOM with 18 sub-modules per arm, connected to a BESS in a single-stage
distributed configuration with first-life lithium-ion battery cells installed in the racks,
was modeled and connected to a balanced three-phase system with a voltage level of
13.8 kV. The ES-STATCOM dynamics during the SoC balancing process were analyzed
in different scenarios, injecting and absorbing active and reactive power at its terminals.
Subsequently, the ES-STATCOM was tested in a modified IEEE 14-bus system to evaluate
its performance during frequency and voltage support, respectively, after the connection of
a large load and the occurrence of a symmetrical fault. The simulation results confirmed
the effectiveness of the proposed control strategy and its ability to maintain SoC balancing
while providing ancillary services to the power grid.
Description
Citation
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto