Análise da correlação entre o protocolo Polar Fitness Test® para predição de VO2máx e ergoespirometria
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
-
Abstract
Introduction: The importance of maximal oxygen consumption (
O
2max
) measurement is justified by its inter
-
national acceptance as the best physiological parameter to assess the functional capacity of the cardiorespiratory
system in both athletes and non-athletes who physically train in order to achieve better health. Objective: To deter
-
mine the agreement between the Polar Fitness Test
®
protocols to estimate of
O
2max
and the maximal exercise test
with direct gas measurement. Methods: Seventeen active males (22.5 ± 2 years) participated in the study. At rest,
the Polar Fitness Test
®
protocol by direct gas collection under maximum effort on treadmill and the Bruce protocol
were applied. Results: Significant difference in the
O
2max
estimation was observed between methods. The Polar
Fitness Test
®
protocol underestimated
O
2max
a mean of 15% (CI
95%
: 24;-53%) when compared to the direct protocol.
The values obtained by the Polar Fitness Test
®
did not correlate well with direct measurement in ergospirometer
(r = 0.1). Conclusion: The Polar Fitness Test
®
protocol is not valid to estimate
O
2max
in physically active young men.
Description
Keywords
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Rights and licensing
Acesso Aberto