Análise da Metodologia SOESGOPE em malha fechada para a Estimação Ótima de Parâmetros de um quadrotor
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
Abstract
There are several methods of optimal parameter estimation. In system identification, a
rich excitation signal is required, which excites the system sufficiently. If the input/output
ratio is not able to generate enough information, any OPE technique will necessarily fail.
The process of identifying closed-loop systems is fundamental for situations in which the
plant has non-linearities and behaviors that are difficult to predict and with stability not
guaranteed for open-loop systems. This work presents an analysis of the SOESGOPE
methodology for estimation of the parameters of a closed-loop system and excitation
signal generation for the experiment. For the identification of closed loop non-linear
systems, a simple controller is needed to preserve the system stable and to allow the
passage of frequencies that adequately sensitize the system. For cases in which the
uncertainties about the parameters complicate the design of the controller, a new approach
to the methodology was proposed, aiming to find a simple and efficient controller for
the estimation of parameters. The proposed new approach find, from the optimization
process in two layers, a set of controllers to keep the system stable and compatible with
with the excitation signal for the parameter estimation process. The new approach of
the SOESGOPE methodology presents positive results for application in UAVs, with
satisfactory performance in the estimation of parameters in all considered cases. The error
obtained in the estimates of the parameters decreased to 1.5% in one of the parameters,
in the new approach, the convergence time of the new algorithm was reduced in the range
of 100 seconds and the entropy of the signals used for the parametric estimation increased
by 3.3646 when compared to the original methodology, ensuring that the information for
the parametric estimation is not lost when the excitation signal is filtered by the system
controller
Description
Citation
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto