Análise de elementos finitos de cinco técnicas de fixação na osteotomia sagital minimamente invasiva
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
There are many studies about fixation techniques in conventional bilateral
sagittal split osteotomy, but little is known about these in anterior oblique sagittal split
osteotomy frequently applied in the minimally invasive approach. The present research
aims to compare five fixation techniques in anterior oblique sagittal split osteotomy,
using finite element analysis. In this in silico study on a hemimandible, an 8 mm linear
advancement was performed, and five 2.0 mm system fixation groups were created:
three bicortical screws in a straight line (group 1); one straight four-hole miniplate
(group 2); one straight four-hole miniplate associated to one bicortical screw (group 3);
one straight four-hole miniplate associated to two bicortical screws (group 4) and one
straight six-hole orthognathic miniplate (group 5). Then, a 260.68 N vertical load at
their first molar was applied. Maximum principal stress at the cortical bone, von Mises
stress on each fixation, stress distribution and distal segment dislocation were
measured and compared between all groups. Groups 1 and 4 presented similar
maximum principal stress and von Mises stress measurements, but dislocation was
lower and stress distribution was better in the last. Group 5 performance was the most
unfavorable among the sample studied, indicating a higher susceptibility to failure from
a clinical perspective.