Surface roughness directly impacts the adhesion of bacteria to ceramic
materials and, consequently, the occurrence of carious lesions, the development of
periodontal diseases and the failure of restoration. It is essential that there are studies
that evaluate polishing and glazing protocols for these materials, as they promote
surface smoothness, contributing to the longevity of the restoration. The present study
evaluated the surface roughness of Celtra Duo glass-ceramic without and with firing
using the following polishing protocols: Optragloss Ceram (OP), Ceramisté (CR), Exa-
Cerapol (EX), PK5 Ceram (PK) and glaze (GL) and bacterial adhesion by quantifying
Colony Forming Units (CFU/mL). 144 specimens were prepared, 72 from Celtra Duo
(CD) and 72 from Celtra Duo with firing (CDQ), which were subdivided into 6 groups
(n=12). The groups were roughened for 20 seconds with a conical diamond bur
(PM95F) and polished for 60 seconds. The average roughness (Ra) was measured.
Streptococcus mutans was grown in BHI and sucrose broth. 50 μL of the inoculum was
deposited on the samples and immersed in BHI and sucrose broth. The biofilm formed
after the incubation period (48 hours) was removed and placed in 1 mL of sterile 0.9%
NaCl. The suspension was stirred and diluted for plating. The plates were incubated
to calculate the CFU/mL of the groups. For statistical analysis, the Jamovi software
was used, considering ∝ as 0.05. ANOVA demonstrated a statistically significant
difference for ceramics (p< 0.001), polishing protocol (p<0.001), as well as for the
interaction between the two variables (p< 0.006). For the variables ceramic, polishing
protocol and CFU/mL, ANOVA showed that for ceramic there was no statistically
significant difference (p= 0.573), there was a statistically significant difference for the
polishing and glazing protocols (p< 0.001) and for the interaction between the two
variables (p< 0.001). The results suggest that there is an impact on microbial adhesion
on the ceramic surface when compared to different treatment protocols, with less
adhesion in all CD and CDQ groups compared to the control group. For CD, groups
GL, EX, CR and PK resulted in lower adherence. For CDQ, CR and PK showed lower
formation of CFU/mL. It is concluded that surface roughness is directly related to
bacterial adhesion. For the analyzed ceramics (CD), firing (CDQ) generated less effect
from the polishing protocols. The PK Protocol proved to be more effective for both